21
REMOTE AND VALVE ACCESS
INNER ACCESS DOOR
The control area can be accessed either through the control door or through the access door inside the firebox.
Follow the door removal instructions. Remove the right side panel. Remove the four screws from the access door.
Note: A new gasket will be required, when
CONTROL DOOR
FIGURE 47
1.Remove the hearth strip.
2.Open the right control door.
3.Remove the switch plate by pull- ing on the left side.
4.Remove the valve housing by pulling on the handle.
5.Lift up and set the housing towards the back of the fire place.
FIGURE 46
FIGURE48
REMOTE RECEIVER REMOVAL
1.Unplug the cord from the junction box
2.Pull the the tab on the receiver lock forward.
3.Pull up on the receiver and disconnect the wires.
4.Install the new receiver (see schematic Pg.23).
VALVE REMOVAL
The valve on the Madison is piped with two flex connectors (one inlet, one outlet).
It can be removed or pulled forward for service.
1.Remove the wing nut and pivot the valve out from the slot at the bottom of the valve.
2.Slowly pull the valve through the control door careful not to kink the gas lines or wires.