Napoleon Fireplaces GD80NT, GD80PT manual Trouble Shooting Guide, Symptom, Problem, Test Solution

Models: GD80NT GD80PT

1 28
Download 28 pages 37.22 Kb
Page 27
Image 27
TROUBLE SHOOTING GUIDE

27

TROUBLE SHOOTING GUIDE

BEFORE ATTEMPTING TO TROUBLESHOOT, PURGE YOUR UNIT AND INITIALLY LIGHT THE PILOT AND THE MAIN BURNER WITH THE GLASS DOOR OPEN.

SYMPTOM

PROBLEM

 

TEST SOLUTION

 

 

 

 

 

 

 

 

Main burner flame

Blockage in vent.

-

remove blockage. In really cold conditions, ice buildup may occur on

is a blue, lazy,

 

the terminal and should be removed as required.

transparent flame.

 

 

 

Incorrect installation.

-

refer to Figure 13 to ensure correct location of storm collars.

 

Flames are consis- Unit is over-fired or under- tently too large or fired.

too small. Carboning occurs.

- check pressure readings:

Inlet pressure can be checked by turning screw (A) counter-clockwise 2 or 3 turns and then placing pressure gauge tubing over the test point. Gauge should read 7" (minimum 4.5") water column for natural gas or 13" (11" minimum) water column for propane. Check that main burner is operating on "HI".

Outlet pressure can be checked the same as above using screw (B). Gauge should read 3.5" water column for natural gas or 10" water column for propane. Check that main burner is operating on "HI".

AFTER TAKING PRESSURE READINGS, BE SURE TO TURN SCREWS CLOCKWISE FIRMLY TO RESEAL. DO NOT OVERTORQUE.

Leak test with a soap and water solution.

Carbon is being de- posited on glass, logs or combustion chamber surfaces.

Air shutter has become

-

ensure air shutter opening is free of lint or other obstructions.

blocked

 

 

 

 

 

Flame is impinging on the

-

check that the logs are correctly positioned.

logs or combustion cham-

-

open air shutter to increase the primary air.

ber.

- check the input rate: check the manifold pressure and orifice size as

 

specified by the rating plate values.

 

- check that the door gasketing is not broken or missing and that the

 

seal is tight.

 

- check that both 4" and 7" vent liners are free of holes and well sealed

 

at all joints.

 

- check that minimum rise per foot has been adhered to for any hori-

 

zontal venting.

White

/ grey film

Sulphur from fuel is being de-

forms.

 

posited on glass, logs or com-

 

 

bustion chamber surfaces.

-clean the glass with a gas fireplace glass cleaner. DO NOT CLEAN GLASS WHEN HOT.

If deposits are not cleaned off regularly, the glass may become per- manently marked.

Exhaust

fumes

Fireplace is spilling.

- check door seal and relief flap seal.

smelled in room,

 

- check for chimney blockage

headaches.

 

- check that the paint curing process is complete

Pilot goes out when

System is not correctly

-

purge the gas line with the glass door open.

the gas knob is re-

purged.

 

 

 

leased.

 

 

 

 

 

 

Out of propane gas.

-

fill the tank.

 

The gas valve has

Pilot flame is not large enough

-

turn up the pilot flame.

an interlock device

which will not al-

 

 

 

 

low

the pilot

Pilot flame is not engulfing the

-

gently twist the pilot head to improve the flame pattern around the

burner to be lit un-

thermocouple.

thermocouple.

til

the

thermo-

Thermocouple shorting /

-

loosen and tighten thermocouple.

couple has cooled.

Allow

approxi-

faulty.

-

clean thermocouple and valve connection.

mately 60 seconds

 

-

replace thermocouple.

 

-

replace valve.

for

the

thermo-

 

 

 

 

 

couple to cool.

Faulty valve.

-

replace.