13
VERTICAL TERMINATION
when (HT) < (VT) | V2 | =10 ft |
|
See graph to determine the required vertical rise VT for the | VT | = V1 + V2 = 5 + 10 = 15 ft |
|
FIGURE 9 |
| FIGURE10 | V2 |
|
|
45°
45°
required horizontal run HT.
For vent configurations requiring more than one 45º and one
90° H2 90°
V1
H1 90°
REQUIRED VERTICAL RISE IN FEET (VT)
150 |
|
|
|
| H1 | =3 ft | ||
140 |
|
|
|
| ||||
130 |
|
|
|
| H2 | =2.5 ft | ||
|
|
|
|
| ||||
120 |
|
|
|
| HR | = H1 + H2 = 3 + 2.5 = 5.5 ft | ||
110 |
|
|
|
| ||||
|
|
|
| HO | = .03(one 45º elbow + three 90º elbows - 135º) | |||
100 |
|
|
|
| ||||
|
|
|
|
| ||||
90 |
|
|
|
|
| |||
|
|
|
| HT | =HR + HO = 5.5 + 5.4 = 10.9 ft | |||
80 |
|
|
|
| ||||
70 |
|
|
|
| HT + VT | = 10.9 + 15 = 25.9 ft | ||
60 |
|
|
|
| Formula 1: | HT < VT | ||
50 |
|
|
|
| ||||
40 |
|
|
|
|
|
| 10.9 < 15 | |
30 |
|
|
|
| Formula 2: | HT + VT < 40 feet | ||
20 |
|
|
|
|
|
| 25.9 < 40 | |
|
|
|
|
|
|
| ||
10 |
|
|
|
| Since both formulas are met, this vent configuration is | |||
0 | 5 | 10 | 15 | 20 | ||||
acceptable. |
| |||||||
|
|
|
|
|
|
HORIZONTAL VENT RUN
PLUS OFFSETS IN FEET
The shaded area within the lines represents acceptable values for HT and VT.
90° elbow , the following formulas apply:
Formula 1: HT < VT |
| ||
Formula 2: HT | + VT | < 40 feet | |
Example 3: |
|
| |
V1 | =5 ft |
|
|