OPERATION / MAINTENANCE

8

OPERATION / MAINTENANCE

OPERATING INSTRUCTIONS

IF THE FIREPLACE IS EQUIPPED WITH DECORATIVE GLASS DOORS, THEY MUST BE FULLY OPENED WHEN OPERATING THIS GAS LOG SET.

LIGHTING INSTRUCTIONS

1.Locate the pilot burner at the rear of the log set on the right side.

2.Turn the gas control knob to the pilot setting (on the left side of the appliance closest to the back).

3.With the control knob depressed, push the piezo igniter continuously until the pilot lights.

Hold the control knob in for 1 minute and release. If the pilot goes out, repeat steps 2 and 3.

4.Once the pilot stays burning, make certain that the on / off switch is in the off position. Turn the control knob counter- clockwise to the on position.

5.Turn the on / off switch to the on position to ignite the burner.

 

1

2

 

3

4

 

5

OXYGEN DEPLETION SENSOR PILOT

CLEANING

This procedure must be performed by a qualified

service person!

Inspect the pilot for any visible contamination or debris (usu- ally lint, pet hair, spider webs, carpet fibre, etc.) and remove.

Disconnect the pilot from the pilot tubing line. Using a 7/16” wrench, remove the injector from the pilot housing. Blow out the housing in the same direction as the gas flow.

Re-install the injector and the pilot tube, turn on the gas and check for leaks.

If this does not improve the performance, replace the pilot with an exact replacement. The device is tamper resistant with no field serviceable parts.

figures 32
CORRECT PILOT
INCORRECT PILOT
FLAME

FLAME

MATCH LIGHTING INSTRUCTIONS

1.Remove any items necessary for easy access to the pilot (for example: logs, screens, etc.).

2.Follow appropriate lighting instructions found previously. Instead of pushing and releasing the piezo button, light a match and hold the flame to the end of the pilot and ignite the pilot.

3.After control knob has been released and pilot stays lit, reinstall any items that were removed for pilot access.

4.Call a qualified service technician for repair or replace- ment of the piezo ignitor.

If heater shuts off, do not relight until you provide fresh air. If heater keeps shutting off, have it serv- iced. Keep burner and control compartment clean.

When lit for the first time, the fireplace will emit a slight odour for a few hours. This is a normal temporary condition caused by the curing of the logs and the "burn-off" of inter- nal paints and lubricants used in the manufacturing proc- ess and will not occur again. Open a window to ventilate the room during this burn off period.

After extended periods of non-operation such as following a vacation or a warm weather season, the fireplace may emit a slight odour for a few hours. This is caused by dust particles burning off. In both cases, open a window to suffi- ciently ventilate the room.

Purge the gas line with the glass door open. Assure that a continuous gas flow is at the burner before closing the door.