Napoleon Fireplaces GLVF18P Air Shutter, Minimum Fireplace Size, Andiron & Grate Assembly, Fuel

Models: GLVF30P GLVF24P

1 12
Download 12 pages 48.44 Kb
Page 5
Image 5
AIR SHUTTER

AIR SHUTTER

LOG SET

AIR SHUTTER

 

 

 

FUEL

NG

LP

GVFL18

9/32"

5/16"

GVFL24

9/32"

5/16"

GVFL30

9/32"

5/16"

The air shutter settings are factory set for most installations. However, adjustment may be required depending on fuel type, vent performance and altitude.

Closing the air shutter will cause a more yellow flame, but can lead to carboning. Opening the air shutter will cause a more blue flame, but can cause flame lifting from the burner ports. The flame may not appear yellow immediately; allow 15 to 30 minutes for the final flame colour to be established.

MINIMUM FIREPLACE SIZE

Each gas log set must be installed into a fireplace cavity with a minimum size.

Refer to the table below to determine the appropriate mini- mum fireplace size.

LOG SET

HEIGHT

WIDTH
DEPTH

 

 

 

 

18"

18"

22"

14"

GVFL18

 

 

 

 

 

 

 

24"

20"

28"

16"

GVFL24

 

 

 

 

 

 

 

30"

22"

34"

20"

GVFL30

 

 

 

 

 

 

 

ANDIRON & GRATE ASSEMBLY

1.With the 2 andirons laying face down, secure the grate overtop using 2x ¼-20 bolts (supplied in the manual baggie).

2.Install the grate/andiron assembly to the burner base using 4x ¾” self tapping screws (supplied in the manual baggie).

5

GAS PIPING

This appliance must be isolated from the gas supply pip- ing system by closing the individual manual shut off valve during any pressure testing of the gas supply piping sys- tem at test pressure equal to or less than ½ psi (3.5 kPa)

1.Centre the appliance in the fireplace opening, making sure the appliance has enough room behind it for the gas line to run behind the log set under the log support.

2.Route the gas line and sizing using piping ½” diameter or greater to allow the full volume of gas to the appliance. The routing of the gas line has to be done to local and / or national codes.

3.When rigid pipe is used an ANSI approved manual shut off and a union must be installed upstream within the fire- place cavity.

4.To ensure the appliance operates reliably install a sedi- ment trap upstream of the appliance within the structures of the piping system.

5.When using propane, a regulator must be used between the tank and the outside wall of the house to ensure the line pressure does not exceed 14” w.c.

6.Check gas connections with a gas detection device to test for leaks in the system. Soapy water mixture can also be used to check for leaks.

7.Once all the gas connections are tested for leaks, start the appliance. Follow the lighting instructions to ensure the appliance is working properly before finishing.

Use only accesso-

ries designed for and

listed with your specific log set.

1

2

W415-0530 / 12.14.05

Page 5
Image 5
Napoleon Fireplaces GLVF18P manual Air Shutter, Minimum Fireplace Size, Andiron & Grate Assembly, Gas Piping, Log Set, Fuel