Napoleon Fireplaces GVF40N, GVF40P manual Symptom, Problem, Test Solution, Pilot

Models: GVF40P GVF40N

1 24
Download 24 pages 11.77 Kb
Page 23
Image 23
Manual background

23

SYMPTOM

PROBLEM

TEST SOLUTION

 

 

 

 

 

 

Pilot

goes

out

Gas piping is undersized.

while

standing;

 

 

 

Main burner is in

 

 

 

'OFF' position.

 

 

 

Flames

are

con-

Unit is over-fired or under-

sistently too large

fired.

 

 

or too

small.

 

 

 

Carboning occurs.

 

B

A

 

 

 

 

OL

 

 

 

 

 

 

 

N

O

 

 

 

 

 

F

 

 

 

 

HI

O

F

 

 

 

 

 

 

 

 

 

 

 

 

P

 

 

 

 

 

 

TOLI

 

 

 

P

 

 

 

 

 

TOLI

 

 

 

Carbon is being Air shutter has become deposited on logs blocked

or combustion

chamber surfaces. Flame is impinging on the logs or combustion cham-

 

ber.

White / grey film

Sulphur from fuel is being

forms on the glass

deposited on glass, logs or

of the optional cata-

combustion chamber sur-

lytic door.

faces.

Exhaust fumes

Not enough combustion air.

 

smelled in room,

 

headaches.

Not enough ventilation air.

 

 

Catalytic tile is masked (con-

 

taminated by dust, paint

 

fumes).

 

Flame is impinging on the

 

logs or combustion cham-

 

ber.

- turn on all gas appliances and see if pilot flame flutters, dimin- ishes or extinguishes, especially when main burner ignites. Monitor appliance supply working pressure.

-check if supply piping size is to code. Correct all undersized piping.

-check pressure readings:

Inlet pressure can be checked by turning screw (A) counter-clock- wise 2 or 3 turns and then placing pressure gauge tubing over the test point. Check with burner operating on "HI". Gauge should read 7" (minimum 4.5") water column for natural gas or 13" (11" mini- mum) water column for propane.

Outlet pressure can be checked the same as above using screw

(B). Check with burner operating on "HI". Gauge should read 3.5" water column for natural gas or 10" water column for propane.

AFTER TAKING PRESSURE READINGS, BE SURE TO TURN SCREWS CLOCKWISE FIRMLY TO RESEAL. DO NOT OVERTORQUE.

Leak test with a soap and water solution.

-ensure air shutter opening is free of lint or other obstructions.

-check that the logs are correctly positioned.

-open air shutter to increase the primary air. See air shutter open- ings, page 13.

-check the input rate: check the manifold pressure and orifice size as specified by the rating plate values.

-clean the glass with a recommended gas fireplace glass cleaner.

DO NOT CLEAN GLASS WHEN HOT.

If deposits are not cleaned off regularly, the glass may become permanently marked.

- increase fresh air supply. (Use one of the methods described in

ANSI Z223.1 Section 5.3 or the applicable local code.)

- increase fresh air supply. (Use one of the methods described in

ANSI Z223.1 Section 5.3 or the applicable local code.)

- check CO output from catalytic tiles. See Maintenance Section.

Replace if necessary.

-

check that the logs are correctly positioned.

-

open air shutter to increase the primary air. See air shutter open-

ings, page 13.

-

check the input rate: check the manifold pressure and orifice size

as specified by the rating plate values.

Remote wall switch is in "OFF" position; main burner comes on when gas knob is turned to "ON" po- sition.

Wall switch is mounted up- side down

Remote wall switch is grounding.

Remote wall switch wire is grounding.

Faulty valve.

- reverse.

- replace.

- check for ground (short); repair ground or replace wire.

- replace.