Napoleon Fireplaces GVF40P, GVF40N manual Options, GVF103-KT- PATENTED CATALYTIC DOOR INSTALLATION

Models: GVF40P GVF40N

1 24
Download 24 pages 11.77 Kb
Page 16
Image 16
OPTIONS

16

OPTIONS

GVF103-KT - PATENTED CATALYTIC

DOOR INSTALLATION

Notes:

Ornamental insets can not be used in conjunction with the catalytic door

When using a catalytic door, glassed doors must be used on all other side or end openings.

This unique patented catalytic system was designed to provide unparalleled safety and peace of mind. The top of the door contains four catalytic tiles which are designed to filter out combustion gases and limit the carbon monox- ide output. It is likely that with the fireplace in operation, the catalytic tiles will actually scrub the carbon monoxide nor- mally found in the room and reduce it to a lower level. The tiles must not be altered or removed. They are not field serviceable and must be tested annually. The hood sup- plied with the unit must be disgarded and replaced with the hood designed for use with the catalytic door.

The heater with an optional catalytic door in place must not be operated when using any products such as paint, paint thinner, adhesives, etc. These products will perma- nently affect the catalytic tiles’ ability to scrub the air.

FIGURES 35

CURTAIN ROD

 

BRACKET

3.Screw the door hinge onto the heater by first start- ing each of the five ma- chine screws and then tightening all screws.

3

TOP DOOR LATCH

4

BOTTOM DOOR LATCH

DOOR HINGE

1

1.The mesh must be removed if the catalytic door is used. Remove the centre bracket and bend the curtain rod slightly to disengage the rod from either side.

LATCH SCREW

LOCATION

CURTAIN SUPPORT PLATE

5

4.& 5. Secure the door using the two latches.

Install the appropriate hood by hooking it over the top lip of the door assembly.

The heater must not be used when the hood is removed.

DOOR OPENING AND CLOSING

2

2.Remove the curtain support plate. Remove the two latch securing screws, already installed, position latch as shown in 4 and re-secure with the screws. A ¼” socket ratchet is recommended for this.

Repeat at the bottom. For location, see 5 .

FLANGE GVF103-KT - PATENTED CATALYTIC

HOODCLIP

UPPERLOUVRE

DOOR LATCH

36

The upper louvres must be removed to allow the catalytic door to be opened or closed. To ac- cess the lower door latch, open the valve control door. Release the top and bottom door latches, lo- cated at the right side of the door.

Care must be taken when closing and opening the cata- lytic door to avoid damaging the catalytic tiles.

W415-0319 / D / 08.03.05

Page 16
Image 16
Napoleon Fireplaces GVF40P, GVF40N manual Options, GVF103-KT- PATENTED CATALYTIC DOOR INSTALLATION, Door Opening And Closing