8

INSTALLATION / FRAMING

!WARNING

Before starting, do the following:

1.For protection wear gloves and safety glasses.

2.Keep hand tools in good condition, sharpen cutting edges and make sure tool handles are secure.

3.Always maintain the minimum air space required to the enclosure to prevent fi res.

 

! WARNING

 

 

 

MAINTAIN THESE MINIMUM CLEARANCES TO

 

 

 

 

COMBUSTIBLES:

 

 

 

 

Fireplace framing:

 

 

 

 

 

 

 

Top Stand-Off

0"

 

Carefully follow the instructions for assembly of the chimney and other

 

 

 

 

 

Rear Stand-Off

0"

 

parts needed to install this fi replace. Failure to do so may result in a fire,

 

 

 

 

 

 

Side

6"

 

especially if combustibles are too close to the fi replace or chimney and

 

 

 

 

 

 

Fireplace finishing:

 

 

 

air spaces are blocked, preventing the free movement of cooling air.

 

 

Sides

63/4"

 

 

 

 

 

 

Top

63/4"

 

LOCATION AND CLEARANCES

 

 

 

 

Factory Built Chimney

2"

 

Do not build shelves or cupboards into the area above

 

 

Hot Air Gravity Ductwork Insulation

1"

the fi replace.

 

*Base of unit to ceiling

72"

While the fi replace can be installed directly on the fl oor, a non-

 

*Base of unit to enclosure top

72"

combustible hearth extension is required in front of the fi replace,

 

Enclosure must have ventilation

between 72" and 84"

that must not be built higher than the bottom of the fi replace to

*84" if installing optional hot air gravity vent system, NZ220 on the

avoid air fl ow blockage. It may therefore be advisable to build the

same fl oor as the fi replace.

 

fi replace on a raised platform. The minimum distance between the

 

 

 

FRAMING

 

edge of the fi replace and any adjacent wall, at right angles to it, is

 

 

 

21". A wall projecting at 45° from the outer edge of the fi replace is

 

 

 

 

NOTE:Inordertoavoidthepossibil-

 

allowed; projections into this area are permitted. Do not install into

 

ityofexposedinsulationorvapour

 

any area having a height less than 6 feet (ceiling to fi replace base,

 

barrier coming in contact with the

 

excluding hearth height). See Section on Framing. The location of

 

fireplacebody,itisrecommended

 

windows, doors and the traffi c fl ow in the room where the stove is

 

that the walls of the fireplace

 

to be located should be considered. If possible, you should choose

 

enclosure be “finished”

 

a location where the chimney will pass through the house without

 

(i.e.: drywall/sheetrock),

 

cutting a fl oor or roof joist.

 

as you would finish any

 

 

 

 

 

 

 

 

 

 

 

 

other outside wall of a

 

 

 

 

 

 

home. This will ensure

 

FIGURE 7a: Framing Requirements

that clearance to com-

 

 

bustiblesismaintained

 

 

 

! WARNING

 

within the cavity.

 

 

 

 

 

 

 

NOTE: Do not build into this area - it must be left clear to provide adequate clearance for the vent in this 14” wide area centered along the front of the fireplace. No combus- tibles are allowed.

3 1/2” MAX

72”

MINIMUM

ENCLOSURE

HEIGHT

FIGURE 7b

14” MAX

11/2”

MAX

25 3/4”

44 3/4” 50 3/4”

W415-0676 / 03.14.08

NorthlineExpress.com

http://www.northlineexpress.com

Toll-Free1-866-667-8454

Page 8
Image 8
Napoleon Fireplaces NZ-26 Installation / Framing, Location and Clearances, Maintain These Minimum Clearances to