INSTALLATION / FRAMING
!WARNING
Before starting, do the following:
1.For protection wear gloves and safety glasses.
2.Keep hand tools in good condition, sharpen cutting edges and make sure tool handles are secure.
3.Always maintain the minimum air space required to the enclosure to prevent fi res.
| ! WARNING |
|
|
| MAINTAIN THESE MINIMUM CLEARANCES TO | |||
|
|
|
| COMBUSTIBLES: |
| |||
|
|
| Fireplace framing: |
| ||||
|
|
|
|
|
| Top | 0" | |
| Carefully follow the instructions for assembly of the chimney and other |
|
| |||||
|
|
| Rear | 0" | ||||
| parts needed to install this fi replace. Failure to do so may result in a fire, |
|
|
| ||||
|
|
| Side | 6" | ||||
| especially if combustibles are too close to the fi replace or chimney and |
|
|
| ||||
|
|
| Fireplace finishing: |
|
| |||
| air spaces are blocked, preventing the free movement of cooling air. |
|
| Sides | 63/4" | |||
|
|
|
|
|
| Top | 63/4" | |
| LOCATION AND CLEARANCES |
| ||||||
|
|
| Factory Built Chimney | 2" | ||||
| Do not build shelves or cupboards into the area above |
|
| Hot Air Gravity Ductwork Insulation | 1" | |||
the fi replace. |
| *Base of unit to ceiling | 72" | |||||
While the fi replace can be installed directly on the fl oor, a non- |
| *Base of unit to enclosure top | 72" | |||||
combustible hearth extension is required in front of the fi replace, |
| Enclosure must have ventilation | between 72" and 84" | |||||
that must not be built higher than the bottom of the fi replace to | *84" if installing optional hot air gravity vent system, NZ220 on the | |||||||
avoid air fl ow blockage. It may therefore be advisable to build the | same fl oor as the fi replace. |
| ||||||
fi replace on a raised platform. The minimum distance between the |
| |||||||
|
| FRAMING |
| |||||
edge of the fi replace and any adjacent wall, at right angles to it, is |
|
|
| |||||
21". A wall projecting at 45° from the outer edge of the fi replace is |
|
|
|
| ||||
NOTE:Inordertoavoidthepossibil- |
| |||||||
allowed; projections into this area are permitted. Do not install into |
| |||||||
ityofexposedinsulationorvapour |
| |||||||
any area having a height less than 6 feet (ceiling to fi replace base, |
| |||||||
barrier coming in contact with the |
| |||||||
excluding hearth height). See Section on Framing. The location of |
| |||||||
fireplacebody,itisrecommended |
| |||||||
windows, doors and the traffi c fl ow in the room where the stove is |
| |||||||
that the walls of the fireplace |
| |||||||
to be located should be considered. If possible, you should choose |
| |||||||
enclosure be “finished” |
| |||||||
a location where the chimney will pass through the house without |
| |||||||
(i.e.: drywall/sheetrock), |
| |||||||
cutting a fl oor or roof joist. |
| |||||||
as you would finish any |
| |||||||
|
|
|
|
|
| |||
|
|
|
|
| other outside wall of a |
| ||
|
|
|
|
| home. This will ensure |
| ||
FIGURE 7a: Framing Requirements | that clearance to com- |
| ||||||
| bustiblesismaintained |
| ||||||
|
| ! WARNING |
| within the cavity. |
| |||
|
|
|
|
|
|
NOTE: Do not build into this area - it must be left clear to provide adequate clearance for the vent in this 14” wide area centered along the front of the fireplace. No combus- tibles are allowed.
3 1/2” MAX
72”
MINIMUM
ENCLOSURE
HEIGHT
FIGURE 7b
14” MAX
11/2”
MAX
25 3/4”
44 3/4” 50 3/4”