ENCLOSURE FINISHING

FIGURE 8a

12”

MAXIMUM

72” MINIMUM ENCLOSURE HEIGHT

VENTILATION

REQUIRED IN

ENCLOSURES

BETWEEN 72”

AND 84”

12”

MAXIMUM

Minimum 40 square inches of ventilation opening required, both at

the top and bottom of the enclosure. Ventilation openings are required in enclosures up to 84” high. They are recommended for all enclosures.

10

ENCLOSURE ALTERNATE FINISHING

FIGURE 8b

1” OPEN

72” MINIMUM ENCLOSURE HEIGHT

VENTILATION

REQUIRED IN

ENCLOSURES

BETWEEN 72”

AND 84”

1” OPEN

Toll-Free 1-866-667-8454

NOTE: As an alternate to grates a 1" x 40 inches wide gap can be left in the bottom and top of any finishing material to circulate the air from the floor, around the fireplace through the enclosure and out the top. If utilizing this method, ensure the fireplace is properly supported and support method does not restrict the flow of air.