WARNING! When reinstalling the burner aer cleaning it is very
important that the valve/orice enters the burner tube before lighng your
gas grill. If the valve is not inside the burner tube a re or explosion could
occur.
Burner: The burner is made from heavy wall 304 stainless steel, but extreme heat and a corrosive environ-
ment can cause surface corrosion to occur. This can be removed with a brass wire brush.
CAUTION! Beware of Spiders.
Spiders and insects are aracted to the smell of propane and natural gas. The burner is equipped with an
insect screen on the air shuer, which reduces the likelihood of insects building nests inside the burner but
does not enrely eliminate the problem. A nest or web can cause the burner to burn with a so yellow or
orange ame or cause a re (ashback) at the air shuer underneath the control panel. To clean the inside of
the burner, it must be removed from the gas grill: Remove the screw (s) that aaches the burner to the back
wall. Slide the burner back and up wards to remove. Cleaning: Use a exible venturi tube brush to clean the
inside of the burner. Shake any loose debris from the burner through the gas inlet. Check the burner ports
and valve orices for blockages. Burner ports can close over me due to cooking debris and corrosion, use
an opened paperclip or the supplied port maintenance bit to clean them. Drill out blocked ports using this
drill bit in a small cordless drill. The ports are easier to clean if the burner is removed from the grill, but it can
also be done with the burner installed. Do not ex the drill bit when drilling the ports, as this will cause the
drill bit to break. This drill is for burner ports only, not for the brass orices (jets) which regulate the ow into
the burner. Take care not to enlarge the holes. Ensure the insect screen is clean, ght, and free of any lint or
other debris.
Reinstallaon: Reverse the procedure to reinstall the burner. Check that the valve enters the burner when
installing. Replace sear plate mount and / or ghten screws to complete reinstallaon.