Chapter 3 Software Installation and Configuration
© National Instruments Corp. 3-5 GPIB-ENET for Macintosh
4. To enter the IP address of your GPIB-ENET, choose the GPIB bus associated with
your box by selecting the bus using the Bus/Device menu. An IP Address edit box
appears below the Bus Timing menu. If you do not know the IP address, see your
network administrator. The IP address you used to configure your GPIB-ENET
hardware is the same IP address you should enter here.
5. Enter your GPIB-ENET box IP address in the edit box. The address should be a
32-bit IP address in IP dot notation (a.b.c.d), or valid domain name syntax. The
IP address can also be an alias as defined in the Hosts file in your System
Folder. Refer to your MacTCP documentation for details on how to properly
assign IP address aliases.
Figure 3-2. NI-488 Config Control Panel
Step 3. Restart Your MacintoshThe NI-488.2 software is installed every time you start or restart your Macintosh. The
NI-488.2 software displays the National Instruments icon momentarily in the lower left
corner of the screen to indicate that the software is being installed. If the National
Instruments icon does not appear on your screen, repeat the installation procedure before
continuing to the next chapter to verify the installation and troubleshoot any problems
that may occur.