Installation Verification and Troubleshooting Chapter 4
GPIB-ENET for Macintosh 4-2 © National Instruments Corp.
Follow these steps to run the software verification test.
1. Disconnect all GPIB cables from the GPIB-ENET.
2. Double-click on the NI-488.2 Test icon in the NI-488.2 folder.
If no error messages are displayed, the installation is complete and you are ready to
write your own application program. Refer to the NI-488.2 Function Reference
Manual for Macintosh for sample programs.
3. If error messages are displayed, restart your Macintosh and double -click on the
NI-488.2 Test icon.
If the test fails again, reinstall the NI-488.2 software from the distribution disk,
restart your Macintosh, and double-click on the NI-488.2 Test icon.
If the verification still fails, carefully note all error information on the GPIB-ENET
Hardware and Software Configuration Form in Appendix C, Customer
Communication, and contact National Instruments.
Troubleshooting Software Problems
The NI-488 Config control panel (GPIB configuration utility) should show the
following software configuration:
The Interface Type box should be set to Ethernet box products.
An X should appear in one of the bus selection boxes to the right of the system
interface menu.
The IP address of the GPIB-ENET should be visible in the IP Address edit box.
Verify that this address is correct.
You can use the NI-488 Config control panel utility to examine and adjust the
configuration of the software. Refer to Chapter 6, GPIB Configuration Utility , in the
NI-488.2 User Manual for Macintosh for more information on running the utility and
for information about the configurable software parameters.
If the software verification test fails, make sure that no GPIB cables are connected to
the GPIB-ENET.