MID-7654/7652Servo Power Motor Drive User Guide 12 ni.com
Theamplifier peak and continuous current limits have been factory set for
5 A continuous current output and 10 A peak current output. Verifythat
these settings are appropriate for your application before powering your
motors.
UseD IP switches 1 through 4 on each ofthe 9-positionD IP switch banks
to set the continuous current limit for each axis. Use DIP switches
5 through8 on each of the 9-position DIP switch banks to set the peak
currentl imit foreach axis. Refer to Figures 1 and 3 for the location of the
continuouscurrent limit and peak current limit switches. Table 5 shows the
DIP switch settings for all possible current limit settings.
Note Theswitches shown in Table 5 show the settings for switches 1 through 4, which are
thecontinuous current DIP switches. Configure the settings for switches 5 through 8 in the
same manner to set thepeak current values.
Table5. Continuous and Peak Output Current DIP Switch Settings
Switch
Continuous
Current(A)
PeakCurr ent
(A) Switch
Continuous
Current(A)
PeakCurrent
(A)
5.00 10.00 1.25 2.50
4.50 9.00 1.15 2.30
3.80 7.55 1.10 2.20
3.00 6.00 1.05 2.10
2.45 4.90 1.00 1.95
2.10 4.20 0.95 1.85
1.95 3.85 0.90 1.80
1.70 3.45 0.85
(default)
1.70
(default)