Chapter 4 Analog Input
© National Instruments Corporation 4-15 NI 6238/6239 User Manual
example, four. The value decrements with each pulse on ai/SampleClock,
until the value reaches zero. The sample counter is then loaded with the
number of posttriggered samples, in this example, three.
Figure 4-10. Pretriggered Data Acquisition Example
If an ai/ReferenceTrigger pulse occurs before the specified number of
pretrigger samples are acquired, the trigger pulse is ignored. Otherwise,
when the ai/ReferenceTrigger pulse occurs, the sample counter value
decrements until the specified number of posttrigger samples have been
acquired.
NI6 238/6239 devices feature the following analog input timing signals.
•AI Sample Clock Signal
•AI Sample Clock Timebase Signal
•AI Convert Clock Signal
•AI Convert Clock Timebase Signal
•AI Hold Complete Event Signal
•AI Start Trigger Signal
•AI Reference Trigger Signal
•AI Pause Trigger Signal
AI Sample Clock SignalUse the AI Sample Clock (ai/SampleClock) signal to initiate a set of
measurements. Your MSeries device samples the AI signals of every
channel in the task once for every ai/SampleClock. A measurement
acquisition consists of one or more samples.
n/a
0123 10222
ai/StartTrigger
ai/ReferenceTrigger
ai/SampleClock
ai/ConvertClock
Scan Counter