Chapter 2 Installation and Configuration
NI PXI-1056 User Manual 2-12 ni.com
Voltage Measurement Commands
Note Units are in VDC.
SF SF:F1: x<CR><LF> Fan #1, x = OK or FAIL
SF:F2: x<CR><LF> Fan #2, x = OK or FAIL
SF:F3: x<CR><LF> Fan #3, x = OK or FAIL
SF:F4: x<CR><LF> Fan #4, x = OK or FAIL
Command Response Description
VA VA: <CR><LF>
V1: +X.XXX<CR><LF>
V2: +X.XXX<CR><LF>
V3: +XX.XX<CR><LF>
V4: -XX.XX<CR><LF>
V5: +X.XXX<CR><LF>
Transmit all voltages as listed below:
Voltage of the +3.3VDC Power supply
Voltage of the +5VDC Power supply
Voltage of the +12VDC Power supply
Voltage of the –12VDC Power supply
Voltage of the +5 VDC VSB Power Supply
V1 V1: +X.XXX<CR><LF> Voltage of the +3.3VDC Power supply
V2 V2: +X.XXX<CR><LF> Voltage of the +5VDC Power supply
V3 V3: +XX.XX<CR><LF> Voltage of the +12VDC Power supply
V4 V4: -XX.XX<CR><LF> Voltage of the –12VDC Power supply
V5 V5: +X.XXX<CR><LF> Voltage of the +5 VDC VSB Power Supply
SP SP:PS: x <CR><LF> Power supply status, x = OK or FAIL
SV SV:V1: x<CR><LF> +3.3VDC supply, x = OK or FAIL
SV:V2: x<CR><LF> +5VDC supply, x = OK or FAIL
SV:V3: x<CR><LF> +12VDC supply, x = OK or FAIL
SV:V4: x<CR><LF> –12VCDC supply, x = OK or FAIL
SV:V5: x<CR><LF> +5VDC VSB supply, x = OK or FAIL
Command Response Description