Chapter 5 Troubleshooting
© National Instruments Corporation 5-3 NI PXI-8104 User Manual
As an alternative method, complete the following steps:
1. Power off the chassis.
2. Remove the controller from the chassis.
3. Move the jumper on W7 from pins 1–2 to pins 2–3 as shown in
Figure 5-1.
4. Wait one second. Move the jumper back to pins 1–2.
5. Reinstall the controller in the chassis.
Caution Do not leave the jumper on pins 2–3. Doing so decreases battery life. Also, the
controller will not boot.
Figure 5-1. Clearing the CMOS Contents
1Normal Operation (Default) 2Clear CMOS Contents 3Pin 1
12
3