Appendix A Specifications
© National Instruments Corporation A-3 NI PXI-8104 User Manual
Operating EnvironmentAmbient temperature range....................5 to 50 °C in an NI PXI-1042
chassis (Tested in accordance
with IEC-60068-2-1 and
IEC-60068-2-2). Refer to the
datasheet linked from the
NIPXI-81 04 Embedded
Controller product page
atni.com fo r other
controller/chassis combinations.
Relative humidity range......................... 10% to 90%, noncondensing
(Tested in accordance with
IEC-60068-2-56.)
Caution Clean the NI PXI-8104 with a soft nonmetallic brush. Make sure that the device
is completely dry and free from contaminants before powering-on the controller again.
Storage EnvironmentAmbient temperature range....................–40 to 65 °C (Tested in
accordance with IEC-60068-2-1
and IEC-60068-2-2.)
Relative humidity range.........................5% to 95% noncondensing
(Tested in accordance with
IEC-60068-2-56.)
Shock and VibrationOperational shock.................................. 30 g peak, half-sine, 11 ms pulse
(Tested in accordance with
IEC-60068-2-27. Test profile
developed in accordance with
MIL-PRF-28800F.)
Random vibration
Operating........................................ 5 to 500 Hz, 0.3 grms
(with solid-state hard drive)