Appendix A Specifications
NI PXI-8183 User Manual A-2 ni.com
Operating EnvironmentAmbient temperature range1...................5 °C to 50 °C2, 3
(Tested in accordance with
IEC-60068-2-1 and
IEC-60068-2-2.)
Relative humidity range..........................10% to 90%, noncondensing
(Tested in accordance with
IEC-60068-2-56.)
Altitude...................................................2,000 m (at 25 °C ambient
temperature)
Pollution Degree.....................................2
For indoor use only.
Caution Clean the PXI-8183 with a soft nonmetallic brush. Make sure that the device is
completely dry and free from contaminants before returning it to service.
Storage EnvironmentAmbient temperature range....................– 40 to 65 °C
(Tested in accordance with
IEC-60068-2-1 and
IEC-60068-2-2.)
Relative humidity range..........................5% to 95% noncondensing
(Tested in accordance with
IEC-60068-2-56.)
Shock and VibrationOperational shock...................................30 g peak, half-sine, 11 ms pulse
(Tested in accordance with
IEC-60068-2-27. Test profile
developed in accordance with
MIL-PRF-28800F.)
1 For chassis not available in the online catalog at ni.com, please contact National Instruments for supported operating
temperatures.
2 5 to 50°C for NI PXI-1036 Revision D and later, and NI PXI-1036DC Revision C and later.
3 5 to 40°C for NI PXI-1036 Revisions B and C and NI PXI-1036DC Revision B.