Chapter 1 Introduction to the LabVIEWOrder Analysis Toolset
LabVIEW Order Analysis Toolset User Manual 1-6 ni.com
tachometer signal and S&V for the sound or vibration sensor. After
choosing data acquisition settings, enter the number of pulses you want the
tachometer to generate per revolution in the Tach Pulse/Rev text box.
Use the controls in the Channel Info section of the Configuration tab to
specify the channel information for the sound or vibration sensor.
After configuring the DAQ device, click the Acquisition tab, shown in
Figure 1-2.
Figure 1-2. Acquire Data (Analog Tach) VI Acquisition Tab
The Acquisition tab, shown in Figure 1-2, allows you to acquire and
observe data. Click the Acquire button to acquire data. Continue to
configure the data acquisition and acquire data until you acquire the data
you want. Click the OK button to return to the front panel of the example
VI to analyze the data.
Acquire Data with PXI 4472 and TIO VIIn digital tachometer examples, setting Data Source to DAQ and clicking
the Run button opens the Acquire Data with PXI 4472 and TIO VI. The
Acquire Data with PXI 4472 and TIO VI helps you acquire vibration data
with a digital tachometer signal. Figure1 -3 shows the Configuration tab
of the Acquire Data with PXI 4472 and TIO VI.