Chapter 3 Signal Connections
PCI-1200 User Manual 3-10 © National Instruments Corporation
Differential Connections for Grounded Signal Sources

Figure3-3 shows how to connect a ground-referenced signal source to a

PCI-1200 board configured for DIFF input. Configuration instructions are

in the Analog I/O Configuration section in Chapter2, Installation and

Configuration.

Figure 3-3. Differential Input Connections for G rounded Signal Sources

With this type of connection, the instrumentation amplifier rejects both the

common-mode noise in the signal and the ground-potential difference

between the signal source and the PCI-1200 ground (shown as Vcm in

Figure3-3).

+
+
Grounded
Signal
Source
V
m
Measured
Voltage
V
s
+
I/O Connector
PCI-1200 in DIFF Configuration
1
3
5
7
2
4
6
8
Common-
Mode
Noise,
Ground
Potential
ACH0
AGND11
ACH2
ACH4
ACH6
ACH1
ACH3
ACH5
ACH7
V
cm
+PC0