Command Reference List
|
| CMD1 | CMD2 | LEN |
01. | Power ON | 9FH | 4EH | 00H |
02. | Power OFF | 9FH | 4FH | 00H |
03. | Input Switch Change | DFH | 47H | 01H |
04. | VOLUME Gain Data | DFH | 7FH | 03H |
05. | SCREEN MODE Select | DFH | 51H | 01H |
06. | AUDIO Mute On | 9FH | 3EH | 00H |
07. | AUDIO Mute Off | 9FH | 3FH | 00H |
08. | OSM Select | DFH | 58H | 01H |
09. | Color Gain Data | DFH | 7FH | 03H |
10. | TINT Gain Data | DFH | 7FH | 03H |
11. | SHARPNESS Gain Data | DFH | 7FH | 03H |
12. | CONTRAST Gain Data | DFH | 7FH | 03H |
13. | BRIGHT Gain Data | DFH | 7FH | 03H |
14. | Input MODE Request | 1FH | 41H | 00H |
15. | RESET | 1FH | 54H | 00H |
16. | COLOR TEMP SELECT | DFH | 00H | 01H |
17. | RED Gain Data | DFH | 7FH | 04H |
18. | GREEN Gain Data | DFH | 7FH | 04H |
19. | BLUE Gain Data | DFH | 7FH | 04H |
20. | VIDEO ADJ Request | 1FH | 45H | 00H |
21. | Audio Select Set | DFH | 70H | 02H |
22. | Audio Select Request | 1FH | 6FH | 00H |
23. | PLE_INVERSE Set | DFH | 6AH | 02H |
24. | Failure Mode Request | 1FH | 3FH | 00H |
01.Power ON
Function
The external control equipment switches on the power of the plasma monitor.
Transmission Data
9FH 80H 60H 4EH 00H CKS
ACK
The plasma monitor returns the following ACK when the power is switched on.
3FH 60H 80H 4EH 00H CKS
03.Input Switch Change
Function
The external control equipment switches the input of the plasma monitor.
Transmission Data
DFH | 80H 60H 47H | 01H DATA00 | CKS |
DATA00 | : Input Select | 01H: Video1 |
|
|
| 02H: Video2 |
|
03H: Video3
05H: HD (HD1 or DTV or DTV1)
06H: HD2 (DTV2)
07H: RGB1/PC1
08H: RGB2/PC2
0CH: RGB3/PC3
ACK
The plasma monitor returns the following ACK when the input is switched. 3FH 60H 80H 47H 00H CKS
04.VOLUME Gain Data
Function
The external control equipment changes the VOLUME gain data of the plasma monitor.
Transmission Data
DFH 80H 60H 7FH 03H DATA00 DATA01 DATA02 CKS
DATA00 | USER SOUND Gain Flag | 05H | |
DATA01 | VOLUME Gain Flag | 01H | |
DATA02 | VOLUME Gain | 00H: Step 0 | |
|
|
|
|
|
| 0AH: Step 10 (Default) | |
|
|
|
|
|
| 2AH: Step 42 | |
ACK |
|
|
|
7FH 60H 80H 7FH 02H | DATA00 DATA01 CKS | ||
DATA00 | USER SOUND Gain Flag |
| 05H |
DATA01 | VOLUME Gain Flag |
| 01H |
02.Power OFF
Function
The external control equipment switches off the power of the plasma monitor.
Transmission Data
9FH 80H 60H 4FH 00H CKS
ACK
The plasma monitor returns the following ACK when the power is switched off.
3FH 60H 80H 4FH 00H CKS
05.SCREEN MODE Select
Function
The external control equipment switches the screen mode of the plasma monitor.
Transmission Data
DFH | 80H | 60H | 51H | 01H | DATA00 | CKS |
DATA00 | 02H | : STADIUM |
|
|
| |
| 03H | : ZOOM |
|
|
| |
| 04H | : NORMAL |
|
|
| |
| 05H | : FULL |
|
|
| |
ACK |
|
|
|
|
|
|
7FH | 60H | 80H | 51H | 01H | DATA00 | CKS |
DATA00 | 02H | : STADIUM |
|
|
| |
| 03H | : ZOOM |
|
|
| |
| 04H | : NORMAL |
|
|
| |
| 05H | : FULL |
|
|
|
38