21.Audio Select Set

Function

The external control equipment sets combinations of audio and video inputs for the plasma monitor.

Transmission Data

DFH

80H 60H

70H 02H DATA00

DATA01

CKS

DATA00:

AUDIO INPUT

 

 

 

01H:

AUDIO 1

 

 

 

02H:

AUDIO 2

 

 

 

03H:

AUDIO 3

 

 

DATA01:

VISUAL INPUT

 

 

 

01H:

Video 1

 

 

 

02H:

Video 2

 

 

 

03H:

Video 3

 

 

 

05H:

HD (HD1 or DTV or DTV1)

 

 

 

06H:

HD2 (DTV2)

 

 

 

07H:

RGB 1/ PC 1

 

 

 

08H:

RGB 2/ PC 2

 

 

 

0CH:

RGB 3/ PC 3

 

 

ACK

The plasma monitor returns the following ACK when the input is switched. 3FH 60H 80H 70H 00H CKS

*The plasma monitor returns “Not Available” when selecting the video input same as the one set at one of the AUDIO 01 to 3.

Example:

The plasma monitor returns “Not Available” when selecting the VIDEO1 for AUDIO2 or VIDEO3 after VIDEO1 has been set to AUDIO1.

22.Audio Select Request

Function

The external control equipment inquires the current combinations of audio and video inputs for the plasma monitor.

Transmission Data

1FH 80H 60H 6FH 00H CKS

ACK

The plasma monitor returns the following ACK:

7FH

60H 80H

6FH 03H DATA00 DATA01 DATA02 CKS

DATA00:

AUDIO 1

 

DATA01:

AUDIO 2

 

DATA02:

AUDIO 3

 

 

VISUAL INPUT DATA

 

01H:

Video 1

 

02H:

Video 2

 

03H:

Video 3

 

05H:

HD (HD1 or DTV or DTV 1)

 

06H:

HD2 (DTV2)

 

07H:

RGB 1 /PC 1

 

08H:

RGB 2 /PC 2

 

0CH:

RGB 3 /PC 3

23.PLE_INVERSE Set

Function

The external control equipment sets the PLE and INVERSE (inverse of image brightness) of the plasma monitor.

Transmission Data

DFH

80H 60H

6AH 02H DATA00

DATA01

CKS

DATA00

: PLE

 

 

 

 

01H:

AUTO

 

 

 

02H:

LOCK

 

 

DATA01

: INVERSE

 

 

 

 

01H:

ON

 

 

 

02H:

OFF

 

 

ACK

The plasma monitor returns the following ACK when setting the PLE and INVERSE (inverse of image brightness):

3FH 60H 80H 6AH 00H CKS

24.Failure Mode Request

Function

The external control equipment inquires the detection of failures of the plasma monitor.

Transmission Data

1FH 80H 60H 3FH 00H CKS

ACK

The plasma monitor returns the following ACK:

7FH 60H 80H 3FH 02H DATA00 DATA01 CKS

DATA00:FILURE MODE 1

Bit 0 : PDP MODULE

 

0: Abnormal

 

1: Normal

Bit 1 :

fixed (backup)

Bit 2 :

TEMPERATURE

 

0: Abnormal

 

1: Normal

Bit 3 :

FAN

 

0: Abnormal

 

1: Normal

Bit 4 :

fixed (backup)

Bit 5 :

fixed (backup)

Bit 6 :

fixed (backup)

Bit 7 :

fixed (backup)

DATA00:FILURE MODE 2

Bit 0–7 : fixed (backup)

43