11.SHARPNESS Gain Data

Function

The external control equipment changes the SHARPNESS gain data of the plasma monitor.

Transmission Data

DFH 80H 60H 7FH 03H DATA00 DATA01 DATA02 CKS

DATA00:

USER PICTURE Gain Flag

01H

DATA01:

SHARPNESS Gain Flag

06H

DATA02:

SHARPNESS Gain

F0H: -16

 

 

 

 

 

 

 

 

 

FFH: -01

 

 

00H: 0

 

 

01H: +01

 

 

 

 

 

 

10H:+16

ACK

 

 

 

7FH 60H 80H 7FH 02H

DATA00 DATA01 CKS

DATA00:

USER PICTURE Gain Flag

01H

DATA01:

SHARPNESS Gain Flag

06H

ACK

7FH 60H 80H 7FH 02H DATA00 DATA01 CKS

DATA00:

USER PICTURE Gain Flag

01H

DATA01:

BRIGHT Gain Flag

08H

14.Input MODE Request

Function

The display returns the current input information by the external control equipment’ s request.

Transmission Data

1FH 80H 60H 41H 00H CKS

ACK

 

 

 

7FH

60H 80H 41H

01H DATA00

CKS

DATA00:

Input Select

 

 

 

01H: Video1

02H: Video2

 

 

03H: Video3

04H: HD (HD1 or DTV or DTV1)

 

05H: RGB1/PC1

06H: RGB2/PC2

 

 

0AH:DVD (DVD1)

0CH:HD2 (DTV2)

 

 

0DH:DVD2

0EH:RGB3/PC3

 

12.CONTRAST Gain Data

Function

The external control equipment changes the CONTRAST gain data of the plasma monitor.

Transmission Data

DFH 80H 60H 7FH 03H DATA00 DATA01 DATA02 CKS

DATA00:

USER PICTURE Gain Flag

01H

DATA01:

CONTRAST Gain Flag

07H

DATA02:

CONTRAST Gain

00H : 0

 

 

 

 

 

 

34H: +52

ACK

 

 

 

7FH 60H 80H 7FH 02H

DATA00 DATA01 CKS

DATA00:

USER PICTURE Gain Flag

01H

DATA01:

CONTRAST Gain Flag

07H

13.BRIGHT Gain Data

Function

The external control equipment changes the BRIGHT gain data of the plasma monitor.

Transmission Data

DFH 80H 60H 7FH 03H DATA00 DATA01 DATA02 CKS

DATA00:

USER PICTURE Gain Flag

01H

DATA01:

BRIGHT Gain Flag

08H

DATA02:

BRIGHT Gain

E0H: -32

FFH: -01

00H: 0

01H: +01

20H: +32

15.RESET

Function

The external control equipment resets the user adjustment of the plasma monitor.

Transmission Data

1FH 80H 60H 54H 00H CKS

ACK

3FH 60H 80H 54H 00H CKS

16.COLOR TEMP SELECT

Function

The external control equipment changes the COLOR TEMP of the plasma monitor.

Transmission Data

DFH 80H 60H 00H 01H DATA00

CKS

DATA00

 

00H: 1

 

01H: 2

 

02H: 3

 

03H: PRO

 

ACK

 

7FH 60H 80H 00H 01H DATA00

CKS

DATA00:

 

00H: 1

 

01H: 2

 

02H: 3

 

03H: PRO

 

NOTE: Set so that at the selection of 1, 2, or 3 of COLOR TEMP change of the following R/G/B GAIN data cannot be accepted. (This must be operated in the same way as OSD menu.)

40