NEC LCD3090WQXi user manual Zoom POS, English-20

Models: LCD3090WQXi

1 34
Download 34 pages 54.92 Kb
Page 22
Image 22

 

H. Size

Adjusts the horizontal size of the screen.

 

(Analog input only)

If the “AUTO Adjust function” do not give you a satisfactory picture setting, a further

 

 

tuning can be performed using the “H.Size (V.Size)” function (dot clock). For this a Moiré

 

 

test pattern could be used. This function may alter the width of the picture. Use left/Right

 

 

Menu to center the image on the screen. If the H.Size (V.Size) is wrongly calibrated, the

 

 

result would look like the left drawing. The image should be homogeneous.

 

 

 

 

Fine

Improve focus, clarity and image stability by increasing or decreasing this setting.

 

(Analog input only)

If the “Auto Adjust function” and the “H.Size” function do not give you a satisfactory

 

 

picture setting, a fine tuning can be performed using the “Fine” function. For this a Moiré

 

 

test pattern could be used. If the Fine value is wrongly calibrated, the result would look

 

 

like the left drawing. The image should be homogeneous.

 

 

 

 

Auto Fine

This function automatically and periodically adjusts the “FINE” setting for change in signal

 

(Analog input only)

condition. This function adjusts approximately every 33 minutes.

 

 

 

 

H. Resolution

Adjusts the horizontal size by increasing or decreasing the setting.

 

 

Press “Right” button to expand the width of the image on the screen.

 

 

Press “Left” button to narrow the width of the image on the screen.

 

 

 

 

V. Resolution

Adjusts the vertical size by increasing or decreasing the setting.

 

 

Press “Right” button to expand the height of the image on the screen.

 

 

Press “Left” button to narrow the height of the image on the screen.

 

 

 

 

Expansion

Sets the zoom method.

 

 

FULL: The image is expanded to 2560 x 1600, regardless of the resolution.

 

 

ASPECT: The image is expanded without changing the aspect ratio.

 

 

OFF: The image is not expanded.

 

 

CUSTOM: When CUSTOM is selected as the Expansion mode, it becomes possible to

 

 

adjust the H. ZOOM., V. ZOOM, and ZOOM POS.

 

 

 

 

H.ZOOM

The image is expanded from 1 to 3 times in the horizontal (H. EXPANSION) direction by

 

(Available in Custom

0.01 increments.

 

Expansion mode only)

 

 

 

 

 

V.ZOOM

The image is expanded from 1 to 3 times in the vertical (V. EXPANSION) direction by

 

(Available in Custom

0.01 increments.

 

Expansion mode only)

 

 

 

 

 

ZOOM POS.

Sets the point from which the screen will be expanded when either H.ZOOM or V.ZOOM is

 

(Available in Custom

selected as the expansion method. Options are CENTER and LEFT TOP.

 

Expansion mode only)

CENTER: H.ZOOM expands the image from the centre outward to the sides of the screen.

 

 

V.ZOOM expands the image from the centre towards the top and bottom of the screen.

 

 

LEFT TOP: Indicates the set point for image expansion (TOP in V. Zoom, LEFT in

 

 

H.ZOOM). If the resolution does not fill out the screen, when expanding, the image will not

 

 

expand past the TOP or the LEFT of the screen. The image can be expanded past the

 

 

right and bottom edges of the screen.

 

 

 

Tag5

Gamma Selection

Allows you to manually select (Gamma function*) the brightness level of grayscale.

 

 

There are five selections:

 

 

NO CORRECTION, 2.2, OPTION, PROGRAMMABLE and CUSTOM.

 

 

NO CORRECTION: No Correction possible.

 

 

2.2: The value is fixed at 2.2.

 

 

PRIORITY: Please refer to the explanation in the CUSTOM selection below.

 

 

OPTION: There are two ways of OPTION selection.

 

 

1: This setting is recommended for Video source. Gray area looks much brighter than

 

 

NO CORRECTION setting.

 

 

2: DICOM gamma is recommended for grayscale medical images. Factory calibrated to

 

 

DICOM Grayscale Display Function for optimum human visual perception.

 

 

PROGRAMMABLE: A programmable gamma curve can be loaded using NEC software.

 

 

CUSTOM: Below items can be adjusted when CUSTOM is selected as the GAMMA

 

 

SELECTION setting.

 

 

Custom Value: The gamma value ranges between 0.5 to 4.0 in 0.1 increments.

 

 

When the COLOR CONTROL is sRGB, the value is fixed at 2.2 and NOT ADJUSTABLE.

 

 

Offset: The OFFSET digitally adjusts the black level after the signal is converted from

 

 

analog to digital.

 

 

PRIORITY: Sets gamma characteristics for optimum viewing of grayscale or color.

 

 

GRAYSCALE: Optimizes gamma for grayscale imaging –should be used with DICOM.

 

 

COLOR: Optimizes gamma for color images.

 

 

*Gamma - The way brightness is distributed across the intensity spectrum by a monitor,

 

 

Gamma is relationship between the input voltage and resulting intensity of the output.

 

 

A perfect linear device would have a gamma of 1.0. A gamma correction function is used

 

 

to alter the luminance (light intensity) of a display such that its brightness (the human-

 

 

perceived value) appears correct.

 

 

 

 

 

English-20

Page 22
Image 22
NEC LCD3090WQXi user manual Zoom POS, English-20

LCD3090WQXi specifications

The NEC LCD3090WQXi is a high-performance 30-inch display that stands out in the realm of professional-grade monitors, particularly in the fields of graphic design, video production, and data visualization. With a resolution of 2560 x 1600 pixels, it offers a stunningly sharp and detailed image that is sure to satisfy even the most demanding users.

One of the standout features of the LCD3090WQXi is its exceptional color reproduction. The display covers an impressive 102% of the sRGB color gamut and about 97% of Adobe RGB, making it an ideal choice for photographers and designers who rely on precise color accuracy. Additionally, the monitor’s 12-bit internal processing allows for over 68 billion colors to be displayed, resulting in smooth gradients and vivid images.

The LCD3090WQXi utilizes IPS (In-Plane Switching) technology, which provides wide viewing angles of up to 178 degrees both horizontally and vertically. This characteristic is crucial for collaborative work environments where multiple people may be viewing the screen at once, ensuring consistent color and brightness irrespective of the viewer's position.

Another significant aspect of the LCD3090WQXi is its ergonomic design. The monitor features height, tilt, and pivot adjustments, allowing users to customize their viewing experience for optimal comfort. This is particularly beneficial for long sessions of graphic design or video editing, where proper posture and screen orientation can reduce eye strain and discomfort.

The connectivity options of the LCD3090WQXi are robust, accommodating a wide range of devices. It includes both DVI-D and DisplayPort inputs, enabling seamless integration with modern graphics solutions. The built-in USB hub offers additional versatility, allowing users to connect peripherals directly to the monitor for increased efficiency.

In terms of calibration, the NEC LCD3090WQXi comes equipped with a built-in ambient light sensor that automatically adjusts brightness based on surrounding lighting conditions. This feature not only enhances image quality but also contributes to energy savings.

Overall, the NEC LCD3090WQXi is more than just a monitor; it is a powerful tool for professionals who demand the very best in color accuracy, image quality, and ergonomic design. Its advanced technologies and features make it a worthy investment for those who thrive in visual-centric industries. Whether for meticulous design work or critical visual analysis, the LCD3090WQXi is engineered to deliver exceptional performance and reliability.