OVERVIEW

DSS/BLF

3.Multiple Dterms cannot use one DSS console.

4.Circuit cards for the DSS are as follows:

PA-16ELCJ

PA-DAIG-A (DAI)

PA-DAIJ-A (DAI)

The previous conditions also apply when a Distributed Access Unit (DAU) is used between the PBX and the DSS.

6.DSS/BLF

One DSS/BLF console requires 2 consecutive ports on an ELC/DAI card.

When a DSS console is used as a DSS/BLF, be sure to assign and wire the DSS/BLF to a specific LEN whose level (LV) is an even number (LV = 0, 2, 4, 6). Since a DSS/BLF requires 2 consecutive ports to program the DSS keys, the port following the designated port, to which the DSS/BLF is wired, must be reserved.

Table 1-4 Level Assignment Conditions for DSS/BLF

LEVEL NUMBER

CONDITIONS

 

 

2n

A DSS console can be connected.

 

 

2n + 1

Must be reserved for the DSS console.

 

 

Note: In Table 1-4, “n” represents 0, 1, 2, 3.

ND-70684 (E)CHAPTER 1

Page 7

Revision 1.0

Page 15
Image 15
NEC NEAX2400IMX system manual PA-16ELCJ PA-DAIG-A DAI PA-DAIJ-A DAI, Dss/Blf