DATA PROGRAMMING

Data Programming Procedure (DSS/BLF)

2.Data Programming Procedure (DSS/BLF)

When assigning DSS/BLF data, perform the following procedure. “X” indicates the value should be tailored to the existing system.

STEP 1: ASYD

Assign the DSS/BLF to an even-numbered LEN level. (In this example LV 0 is used.) TN : X

STN : 200

LEN : 0 0 0 1 0 0 Even-numbered LEN level

TEC : 1 2 Fixed

RSC : X

SFC : X

Assign a station to be used for programming DSS keys (KYNs 31-60) to the subsequent LENS. (In this example, LV 1 is used.

TN

:

X

 

 

 

 

 

STN :

201

 

 

 

 

 

LEN :

0 0 0 1 0 1

 

 

 

Subsequent LEN level

 

 

 

TEC

:

1 2

 

 

 

 

Fixed

 

 

 

 

RSC :

X

 

 

 

 

 

SFC

:

X

 

 

 

 

 

STEP 2: AKYD

Assign key data for the 60 DSS keys. The upper 30 DSS keys (KYNs 1-30) are assigned using the first port (LV 0 in this example) and the remaining lower DSS keys (KYNs 31-60) are assigned using the second port (LV 1 in this example). Either KYN 1 or KYN 2 can be assigned first.

Be sure to assign the associated Dterm station number as the “Station Number of Prime Line.”

TN

:

X

 

 

STN

:

200 or 201

 

 

TP

:

1

 

 

 

Buttons 1-40 are assignable

 

 

PRI

:

0

 

 

 

 

PL TN

:

X

 

Enter the associated Dterm as a PL STN.

PL STN

:

400

 

 

 

 

 

 

S

:

0

 

 

 

= Off Hook Suppression is off

MWD

:

0

 

 

 

 

LN PRE

:

0

 

 

 

= Prime Line Pickup

KYN 1 must be programmed as the DSS/BLF station that has been assigned by the ASDT command.

KYN

:

1

 

 

 

KY1

:

2

 

 

= Multi Line

KD

:

0

 

 

= Line

TN

:

X

 

 

 

STN

:

200 or 201

 

 

DSS/BLF number

 

 

RG

:

X

 

 

 