OVERVIEW

Add-On Module

The following features cannot be used when a DSS/BLF console encounters a busy station.

CALL BACK

CALL WAITING

EXECUTIVE RIGHT-OF-WAY

STEP CALL

A station user cannot activate the following features for an incoming call from a DSS/BLF console. Note

CALL FORWARDING-OUTSIDE (including ALL CALLS, BUSY LINE, DON’T ANSWER)

MULTIPLE CALL FORWARDING (including ALL CALLS, BUSY LINE, DON’T ANSWER)

STATION HUNTING

Note: UNIFORM CALL DISTRIBUTION can be activated for an incoming call from a DSS/BLF as usual when this feature has been set to the terminal.

7.Add-On Module

A maximum of 48 lines and 12 feature keys may be programmed for an Add-On Module. One Add-On Module occupies only one port on an ELC/DAI card.

When a DSS console is used as an Add-On Module, be sure to assign the DSS console to a specific LEN whose level (LV) is an odd number (LV = 1, 3, 5, 7). Also, the Dterm used in conjunction with the Add-On Module

must be assigned to the preceding even-numbered LEN level (LV = 0, 2, 4, 6).

Table 1-5 Level Assignment Conditions for the Add-On Module Mode

LEVEL NUMBER

CONDITIONS

 

 

2n + 1

Add-On Modules are connected.

 

 

2n

The Dterms which use keys on the Add-On Modules as additional Line Feature

access keys are connected.

 

 

 

Note: In Table 1-5, “n” represents 0, 1, 2, 3.

CHAPTER 1

ND-70684 (E)

Page 10

Revision 1.0

Page 18
Image 18
NEC NEAX2400IMX system manual Call Back Call Waiting Executive RIGHT-OF-WAY Step Call, Station Hunting, Add-On Module