CONFIDENTIAL
PLE LINK
Use this function to set a uniform brightness for each display.
Turn on the AUTO ID and set the DIVIDER (at 1, 4 or 9) before the following operations.
Example: Setting “ON”
On “ PLE LINK” of “ VIDEO WALL” menu, select “ ON” , then press the MENU/ENTER button.
|
|
|
| VIDEO WALL |
|
|
DIVIDER | : | 1 |
| |||
POSITION |
|
|
| |||
DISP. MODE | : | SPLIT | ||||
AUTO ID | : | OFF | ||||
IMAGE ADJUST |
|
|
| |||
P. ON DELAY | : | OFF | ||||
| PLE LINK |
| : | ON | ||
|
|
|
|
|
| |
REPEAT TIMER | : | OFF | ||||
|
| SEL. | ADJ. | EXIT | RETURN |
Information
⬛PLE LINK settings
ON: Sets a uniform brightness for each screen in a video wall. This can be set only when a 2⋅ 2 or 3⋅ 3 video wall is selected.
OFF: Sets the individual screen brightness for each screen in a video wall.
*When this function is set “ ON” , connect your plasma
displays with the remote cable (optional) in the order of the position numbers for the 2⋅ 2 video wall. See the
drawing below.
*If there are changes in the DIVIDER or POSITION, the PLE LINK will automatically turn OFF.
|
| REPEAT TIMER | ||
1 | DIVIDER | : | 1 |
|
| SOURCE | : | VIDEO1 | |
| WORK TIME | : | 00H03M | |
2 | DIVIDER | : | 4 |
|
| SOURCE | : | RGB1 | |
| WORK TIME | : | 00H06M | |
| SEL. | ADJ. |
| RETURN |
| EXIT |
Information
⬛REPEAT TIMER settings
DIVIDER: Divide the screen into 1, 4 or 9 sections.
SOURCE: Set the input mode to be displayed.
WORK TIME: Can be set to up to 4 hours 15 minutes in units of 1 minute.
If you set both timers, Timer 1 and Timer 2 run consecutively.
In the case of the Video wall, timer No.1 can be used to control all the displays simultaneously.
*This becomes effective when the
REMOTE IN
REMOTE OUT
No.1 No.2
No.4 No.3
Display 1
No.1 No.2
No.4 No.3
Display 4
REMOTE
OUT
REMOTE IN
REMOTE
OUT
REMOTE IN
No.1 No.2
No.4 No.3
Display 2
No.1 No.2
No.4 No.3
Display 3
REMOTE OUT
REMOTE IN
*With the 3⋅ 3 video wall, connect the final display to the first display the same way as with 2⋅ 2 video wall.
Note: The remote control can be operated unless the
IR REMOTE is set to “OFF”.
REPEAT TIMER
Use this to set two timers. Each timer can use the DIVIDER, SOURCE and WORK TIME.
Turn on the AUTO ID and set the DIVIDER (at 1, 4 or 9) before the following operations.
Example:
TIMER1...VIDEO1 will be displayed for 3 minutes. TIMER2...RGB1 will be displayed for 6 minutes in a
2⋅ 2 video wall.
On “ REPEAT TIMER” of “ VIDEO WALL” menu, select
“ON” , then press the MENU/ENTER button. The “ REPEAT TIMER” screen appears. Adjust the items.