User’s Manual U16214EJ1V0UM 43
APPENDIX B CAUTIONS ON DESIGNING TARGET SYSTEM
Figures B-1 and B-2 show the conditions when connecting the emulation probe to the conversion connector.
Follow the configuration below and consider the shape of parts to be mounted on the target system when designing a
system.
In the product names described in this appendix, SWEX-120SE-1, NQPACK120SE, YQPACK120SE, and YQ-
GUIDE are products of TOKYO ELETECH CORPORATION.
Figure B-1. Distance Between In-Circuit Emulator and Conversion Socket
303 mm
In-circuit emulator
IE-78K0-NS or IE-78K0-NS-A
Emulation board
IE-780338-NS-EM1
Conversion connector
NQPACK120SE,
YQPACK120SE,
YQ-GUIDE
Target system
Emulation probe
SWEX-120SE-1
CN5