This device cannot be used or installed without the Tabletop Stand or other mounting accessory for support. For proper installation it is strongly recommended to use a trained, NEC authorized service person. Failure to follow NEC standard mounting procedures could result in damage to the equipment or injury to the user or installer. Product warranty does not cover damage caused by improper installation. Failure to follow these recommendations could result in voiding the warranty.

Mounting

DO NOT mount the monitor yourself. Please ask dealer. For proper installation it is strongly recommended to use a trained, qualifi ed technician. Please inspect the location where the unit is to be mounted. Mounting on wall or ceiling is the customer’s responsibility. Not all walls or ceilings are capable of supporting the weight of the unit. Product warranty does not cover damage caused by improper installation, remodelling, or natural disasters. Failure to comply with these recommendations could result in voiding the warranty.

DO NOT block ventilated openings with mounting accessories or other accessories.

For NEC Qualified Personnel:

To ensure safe installation, use two or more brackets to mount the unit. Mount the unit to at least two points on the installation location.

Please note the following when mounting on wall or ceiling

When using mounting accessories other than those that are NEC approved, they must comply with the VESA- compatible (FDMlv1) mounting method.

V462 only: NEC strongly

Unit No gap

Mounting

recommends using size

 

 

 

 

 

 

Bracket

 

 

 

 

 

 

 

M6 screws (15-16 mm +

 

 

 

 

 

 

Washer

thickness of bracket

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

￿ 8.5 mm (V462)

 

 

 

Screw

and washer in

 

 

 

￿ 10.0 mm (V651)

 

 

 

 

 

 

 

 

 

length). If using

 

 

 

 

 

 

 

15-16 mm

 

 

Thickness

 

 

 

screws longer than 15-16 mm,

of bracket

check the depth of the hole.

 

 

 

 

 

 

 

 

 

 

 

 

and washer

(Recommended Fasten

Screw length should equal

Force: 470 - 635N•cm)

depth of hole (15-16 mm) +

NEC recommends mounting

the thickness of mounting

interfaces that comply with

bracket and washer. Bracket

UL1678 standard in North

hole should be under ￿ 8.5 mm

(V462), ￿ 10.0 mm (V651).

America.

 

V651 only: NEC strongly recommends using size M8 screws (15-16 mm + thickness of bracket in length). If using screws longer than 15-16 mm, check the depth of the hole. (Recommended Fasten Force: 1125 - 1375N•cm) NEC recommends mounting interfaces that comply with UL1678 standard in North America.

Prior to mounting, inspect the installation location to insure that it is strong enough to support the weight of the unit so that the unit will be safe from harm.

Refer to the instructions included with the mounting equipment for detailed information.

Make sure there is no gap between the monitor and the bracket.

Orientation (V462 only)

When using the monitor in the portrait position, the monitor should be rotated clockwise so that the left side is moved to the top and the LED indicator light is on the bottom. This will allow for proper ventilation and will extend the lifetime of the monitor. Improper ventilation may shorten the lifetime of the monitor.

Orientation (V651 only)

DO NOT use this monitor in the portrait position. Doing so may cause failure and void the warranty.

Mounting location

The ceiling and wall must be strong enough to support the monitor and mounting accessories.

DO NOT install in locations where a door or gate can hit the unit.

DO NOT install in areas where the unit will be subjected to strong vibrations and dust.

DO NOT install near where the main power supply enters the building.

Do not install in where people can easily grab and hang onto the unit or the mounting apparatus.

When mounting in a recessed area, as in a wall, leave at least 4 inches (100 mm) of space between the monitor and the wall for proper ventilation.

Allow adequate ventilation or provide air conditioning around the monitor, so that heat can properly dissipate away from the unit and mounting apparatus.