CHAPTER 1 OVERVIEW
User’s Manual U15447EJ1V0UM 15
1.6 Connection Between IE-703002-MC and IE-703079-MC-EM1
The procedure for connecting the IE-703002-MC and IE-703079-MC-EM1 is described below.
Caution Connect carefully so as not to break or bend connector pins.
<1> Remove the pod cover (upper and lower) of the IE-703002-MC.
<2> Set the PGA socket lever of the IE-703079-MC-EM1 to the OPEN position as shown in Figure 1-4 (b).
<3> Connect the IE-703079-MC-EM1 to the PGA socket at the back of the IE-703002-MC pod (refer to Figure 1-4
(c)). When connecting, position the IE-703002-MC and IE-703079-MC-EM1 so that they are horizontal.
<4> Set the PGA socket lever of the IE-703079-MC-EM1 to the CLOSE position as shown in Figure 1-4 (b).
<5> Set the IE-703002-MC pod jumpers (JP1 to JP3).
The factory settings of JP2 are pins 1 and 2 shorted.
<6> Place the supplied spacers in the four corner holes of the IE-703079-MC-EM1. Fix the spacers with the
supplied screws.
<7> Fix the IE-703002-MC pod cover (upper) end with nylon rivets.