Technical Specifications
General Specifications |
| Model FS102 Switch |
| Model FS104 Switch |
| Model FS108 Switch |
|
|
|
|
|
|
|
Network Protocol and |
| ISO/IEC | ||||
Standards Compatibility |
| IEEE 802.3u, IEEE802.3x | ||||
|
|
| ||||
Data Rate |
| 100 Mbps with 4B/5B encoding and | ||||
|
| 10 Mbps differential Manchester encoded | ||||
|
|
| ||||
Interface |
| |||||
|
|
|
|
|
|
|
Power Consumption |
| 8 W |
| 15.2 W |
| 12 W |
|
|
|
|
|
|
|
Input Voltage |
| 12 V dc |
| 12 V dc |
| 5 V dc |
(Power Adapter) |
|
|
|
|
|
|
|
|
|
|
|
|
|
Physical Specifications |
|
|
|
|
|
|
Dimensions: |
| 6.2 x 1.06 x 4.1 in. |
| 9.27 x 1.06 x 4.1 in. |
| 9.27 x 1.06 x 4.1 in. |
|
| 15.8 x 2.7 x 10.3 cm |
| 23.5 x 2.7 x 10.3 cm |
| 23.5 x 2.7 x 10.3 cm |
Weight: |
| 1.09 lb; 0.50 kg |
| 1.60 lb; 0.73 kg |
| 1.60 lb; 0.73 kg |
|
|
|
|
|
|
|
Environmental Specifications |
|
|
|
| ||
Operating temperature: |
|
|
| 0Gto 40GC (32Gto 104GF) |
|
|
|
|
|
|
| ||
Operating humidity: |
| 90% maximum relative humidity, noncondensing | ||||
|
|
| ||||
Electromagnetic |
| CE mark, commercial; FCC Part 15, Class A; EN 55 022 (CISPR 22), Class A; | ||||
Emissions |
|
|
| VCCI Class 1 ITE |
|
|
|
|
|
|
|
|
|
Electromagnetic Susceptibility |
|
|
|
| ||
|
| CE mark, commercial |
| CE mark, commercial |
| CE mark, commercial |
|
|
|
| |||
Electrostatic discharge |
| IEC |
| IEC |
| IEC |
(ESD): |
|
|
|
|
|
|
Radiated electromagnetic |
| IEC |
| IEC |
| IEC |
field: |
|
|
|
|
|
|
Electrical fast transient/burst: |
| IEC |
| IEC |
| IEC |
Electrical surge: |
| IEC |
| IEC |
| IEC |
|
|
|
|
|
|
|
Safety Agency Approvals |
| CE mark, commercial |
| CE mark, commercial |
| CE mark, commercial |
for Power Adapter |
| UL listed (UL 1950) |
| UL listed (UL 1950) |
| UL listed (UL 1950) |
|
| CSA certified |
| CSA certified |
| CSA certified |
|
| (CSA 22.2 #950) |
| (CSA 22.2 #950) |
| (CSA 22.2 #950) |
|
| TUV licensed |
| TUV licensed |
| TUV licensed |
|
| (EN 60 950) |
| (EN 60 950) |
| (EN 60 950) |
|
|
|
| |||
|
|
|
|
|
|
|
Performance Specifications |
|
|
|
|
|
|
|
|
|
|
| ||
Frame filter rate: |
| 14,800 frames/second, maximum on 10 Mbps port | ||||
|
| 148,000 frames/second, maximum on 100 Mbps port | ||||
Frame forward rate: |
| 14,800 frames/second, maximum on 10 Mbps port | ||||
|
| 148,000 frames/second, maximum on 100 Mbps port | ||||
Network latency (using 64- |
| 10 Mbps to 10 Mbps: 73 microseconds maximum | ||||
byte packets): |
| 10 Mbps to 100 Mbps: 26 microseconds maximum | ||||
|
| 100 Mbps to 10 Mbps: 62 microseconds maximum | ||||
|
| 100 Mbps to 100 Mbps: 15 microseconds maximum | ||||
Address database size: |
| 8,000 media access control (MAC) addresses per port | ||||
Addressing: |
|
|
|
|
| |
|
|
|
|
| ||
Queue buffer: |
| 10/100 Mbps ports: 1 MB of buffer space |
| 10/100 Mbps ports: 128 k | ||
|
| for each port |
| of buffer space for each | ||
|
|
|
|
|
| port |
|
|
|
|
|
|
|
Model FS102, Model FS104, Model FS108 Fast Ethernt Switch Installation Guide