Command Mode

Function:

Increment Port

Decrement Port

Keystroke:

I

or

(select the next higher port

ex. 01

02)

D

or

(select the next lower port

ex. 02

01)

or

+

-

KEY SYMBOLS LEGEND:

PRESS EITHER KEY

CHORDED SEQUENCE- PRESS CONSECUTIVELY AND KEEP KEYS PRESSED UNTIL ALL ARE PRESSED.

PRESS CONSECUTIVELY

Toggle Scan Mode ON and OFF

S

(When toggled to ON, Scan Mode will be indicated the LED for only the active CPU

flashing ON and OFF .)

 

Sets scan time-out

T

-

(0-2)

-

(0-9)

-

(0-9)

(xxx from 002 to 255. ie. t002

would set the time-out period

period for each port.

x

x

x

for 2 seconds)

Toggle Broadcast Mode ON and OFF

B

(When toggled to ON, Broadcast Mode will be indicated by both LEDs cycling alternately

ON and OFF in rapid intervals.)

Selects a specific port

Select a different control key combination

Select a specific country code for the keyboard

P - 0 -

C - x

L - x -

(1-2)

(P0x would be P01 or P02.)

x

 

x = the desired key (This will replace the Ctrl + ` sequence to enter Command Mode)

x

(Lxx would be L00-L34, see Country Codes Table on page 9)

Print the code version to a text editor

V

(This will print the version of the code in the KEEMUX-USBV-2U switch to a text editor

window for use when troubleshooting the switch)

Configure port to connect To a MAC CPU

Configure port to connect To a WINDOWS or SUN CPU

Exit Command Mode

M

+

x

(x= 1 or 2 <M> + <1> will enable function on Port 1

<M> + <2> will enable function on Port 2. Keyboard

 

LED's will flash once to confirm command. )

W

+

x

(x= 1 or 2 <W> + <1> will disable function on Port 1

<W> + <2> will disable function on Port 2. Keyboard

 

LED's will flash once to confirm command. )

 

 

 

 

 

Esc

 

 

Note: The user must exit Command

 

 

 

Mode to use the CPU(s) in the

 

 

 

 

selected mode.

 

 

 

 

 

 

 

Default Value Reset

Default factory-set values for Command Mode entry key, Scan dwell time and country code can be restored by following this procedure:

1.Disconnect power from the UNIMUX-USBV-2 USB KVM switch

2.Press and hold the CPU SELECT button on the switch

3.Re-connect power to the switch

4.Release the CPU SELECT button

6

Page 8
Image 8
Network Technologies MAN027 manual Command Mode, Default Value Reset, Function, Keystroke, Flashing on and OFF