8.4Synchronization
The AES42 standard describes the following two modes for synchronizing the microphone with the receiver (e.g. a mixing console or the
Mode 1: The microphone operates asynchronous- ly, using the sampling rate of its internal quartz oscillator. In this case, a sample rate converter is required at the receiver.
Attention: This mode should be used only when it is not possible to use mode 2 synchroniza- tion, since signal quality can be expected to be impaired by standard sample rate converters (in terms of dynamic range and latency time).
Mode 2: The microphone operates synchronously with a master word clock. This can be an external word clock, or the internal word clock of the
Via the BNC output, the internal word clock generator can be used to synchronize additional DMIs and connected equipment, such as a mixing console.
Problem | ▶ Possible causes | ▶ Solution | |
The “DATA VALID” LED is not lit up, | No valid data stream – Cause: | Check to ensure a continuous | |
even though a microphone is con- | The microphone cable connection | cable connection. | |
nected and switched on. (The RCS |
| ||
is faulty or too long. | Comply with the recommended | ||
“AES 42 PWR” display is lit up). | |||
| maximum cable length and | ||
|
| ||
|
| required cable quality, as appli- | |
|
| cable for the selected word clock | |
|
| frequency. Avoid unnecessary | |
|
| transition points (connectors). See | |
|
| Section 8.2, Cables. | |
| The microphone is defective. | Use a microphone that is in good | |
|
| working order. | |
The “SYNC LOCKED” LED blinks | The microphone has not been | Select a word clock frequency that | |
continuously. (Blinking for a short | synchronized because the se- | it is supported by all of the con- |
US
GB
9. Troubleshooting
Problem | ▶ Possible causes | ▶ Solution | |
The RCS does not indicate that a | The DMI is not recognized by the |
| |
microphone is switched on and | RCS software. – Cause: |
| |
connected to the DMI, even though | The DMI was not switched on | Do not start the RCS until the DMI | |
the “DATA VALID” LED on the DMI | |||
at the time when the RCS was | has been switched on; or execute | ||
is lit up. | |||
started. | the command Options/DMI and | ||
| |||
|
| then close the window again. | |
| An ID has been used that is not | Currently only the IDs 0, 1, 2 and | |
| currently supported by the RCS, | 3 are supported. Set the ID by | |
| or the same ID has been used for | means of the coding switch on the | |
| more than one DMI. | back of the DMI; each DMI must | |
|
| have a different ID! | |
| The ID has been changed while the | After an ID is changed, the DMI | |
| DMI was in operation. | must be restarted. Then restart | |
|
| the RCS; or execute the command | |
|
| Options/DMI and then close the | |
|
| window again. | |
| Incorrect interface setting (USB, | Select the correct interface in the | |
| COM1 or COM2). | RCS via the command Options/ | |
|
| Communication. | |
The “Ext. Word Clk” LED is not lit | No word clock signal has been | Check the source of the word clock | |
up, even though an external word | detected. | signal and the cable connection. | |
clock has been connected. |
|
| |
The “Ext. Word Clk” LED blinks | A word clock signal is present, | Check the word clock frequency or | |
continuously. (Blinking for a short | but has not been interpreted as a | select another source for the word | |
period following activation of an | valid signal. This can occur, for ex- | clock signal. Alternatively, remove | |
external word clock is normal, and | ample, if the word clock frequency | the external word clock and use | |
indicates that the synchronization | deviates by more than ±50 ppm | the DMI internal word clock as the | |
process is being carried out). | from the nominal value. | master word clock for the signal | |
|
| chain. | |
16 |
|
|
period during the synchronization | lected word clock frequency is not | nected microphones. |
process is normal). | supported. |
|
The “SYNC LOCKED” LED is not lit | The microphone is operating in | Set a sampling rate for synchro- |
up. | asynchronous mode. (This is indi- | nous mode or set “Sync to Ext. |
| cated by the letter “a” preceding | Word Clk”. |
| the frequency display in the RCS |
|
| word clock window). |
|
| The microphone supports only | Use a microphone that can be |
| “mode 1” in accordance with the | synchronized (e.g. any Neumann |
| AES 42 standard, i.e. it cannot be | |
| synchronized. |
|
Functions cannot be controlled via | Control via the user port has not | In the RCS system menu, “Func- |
the user port. | been activated. | tion controlled by user port” |
|
| must be activated for the relevant |
|
| functions. |