OBSERVED | POSSIBLE |
|
|
|
PROBLEM | CAUSE |
|
| SOLUTION |
|
|
|
|
|
1. Igniter button is pressed. No 1. | Igniter electrode positioned | 1. | Replace igniter | |
spark at ODS/Pilot | incorrectly |
|
|
|
2. | Igniter electrode broken | 2. | Replace igniter | |
3. | Igniter electrode not | 3. | Reconnect igniter cable | |
| connected to igniter cable |
|
|
|
4. | Igniter cable pinched or wet | 4. | Free igniter cable if pinched | |
|
|
|
| by any metal or tubing. Keep |
|
|
|
| igniter cable dry. |
5. | Piezo igniter nut is loose | 5. | Tighten nut holding piezo | |
|
|
|
| igniter to heater cabinet. Nut |
|
|
|
| is located inside heater |
|
|
|
| cabinet at top. |
6. | Broken igniter cable | 6. | Replace igniter cable | |
7. | Bad piezo igniter | 7. | Replace piezo igniter | |
|
|
|
|
|
2.Igniter button is Spark at ODS/Pilot No Ignition
pressed 1. | Gas supply turned off or | 1. | Turn on gas supply or open |
| manual shutoff valve is |
| manual shutoff valve |
| closed |
|
|
2. | Control knob not in “PILOT” | 2. | Turn control knob to “PILOT” |
| position |
| position |
3. | Control knob not pressed in | 3. | Press in control knob while in |
| while in “PILOT” position |
| “PILOT” position. |
4. | Air in gas lines when installed 4. | Continue to hold down control | |
|
|
| knob. Repeat igniting |
5. | Depleted gas supply |
| operation until air is removed. |
|
| 5. | Contact local propane gas |
6. | ODS/Pilot is clogged |
| company |
|
| 6. | Clean ODS/Pilot or replace |
7. | Gas regulator setting is not |
| ODS/Pilot assembly |
| correct | 7. | Replace gas regulator |
32