E. Vertical exit into masonry flue using (6" Single Wall pipe minimum 24 ga blued or black pipe with elbow) With standard close clearance shield and pipe shield.
Model 261 minimum clearance to combustibles.

Figure 11.
MASONRY CHIMNEY
CLEAN OUT
DOOR
MASONRY
FLUE
LINERS
CEILING
MASONRY CHIMNEY
Figure 12.
SINGLE WALL
CONNECTOR
ELBOW PIPE
BACK
WALL
A
E
B
F
D
G
CC
C
C

A B C D E F G H

MODEL 261 13” 8" 13" 12" 8" 3" 16" 10"
A
E
B D
F
BACK WALL
SIDE WALL
PROTECTOR
G
NEW BUCK
CAST COLLAR
Part# MA6CHIMCNB
Maintain 18"Minimum Clearance

NOTE: All clearances are to combustibles with all low clearance shields and single wall pipe

with elbow, and minimum floor protector.NOTE: Floor protector must extend length of

horizontal flue pipe to wall. NOTE: Model 261 comes standard with low clearance shields.

H
NOTE: