Timer

For all of the following TIMER programming, proceed firstly with these standard

steps:

Press the Timer button briefly, the 2 digits on the control panel will show 00.

Press the Sleep mode button again to program the timer for ON – when the unit is OFF or program the timer for OFF – when the unit is RUNNING. The time

will be increased by hour from 00, 01, 02…..24, thence go back from 24, 23,

22…..00 by each press of the Dehumidification button.

Press the Heat (optional function) button briefly to adjust the time as 00 to cancel the timer function.

Sleep mode

The sleep mode function adjusts the set temperature of the unit to the thermal needs of the body falling asleep as follows:

Default fan speed: Low

Press the Manual background button to operate the sleep mode. Press the Manual background button again

in order to cancel the sleep mode. The set temperature will increase 2after 1 hour and a further 2after 2 hours.

No FAN ONLY / DEHUMIDIFICATION mode under SLEEP mode operation.

Dehumidification

If the unit will be used mainly as a dehumidifier just let the warm air return in the room. Continuous drainage (see separate chapter) is then necessary and more efficient. Only low fan speed under dehumidifying.

Heat (optional function)

The unit features a heat pump that can heat a room on cooler days. With the mode switch select ‘heat’ with the temperature in 68as default. You can set the desired temperature and the unit will heat until this temperature is reached.

Do not place the unit near anything that could catch fire or be scorched. Do not obstruct the air outlet.