If LAM was exposed to salt water it should be rinsed in fresh water and dried outside at no more than 55oC.

Long-term storage

When preparing for long-term storage, cover the external metal surfaces of LAM with protective lubricant. Each 4 (four) years old layer of lubricant should be removed and new layer be applied.

To remove old layer of lubricant:

-Wipe LAM with clean dry cloth,

-Degrease metal surfaces of LAM with benzene moistened cloth,

-Dry LAM out-of-doors.

Do not touch unit’s metal surfaces with fingers after

cleaning.

To apply new layer of lubricant:

-Within two hours from the cleaning apply an even 0.2-0.5 mm thick layer of lubricant on metal surfaces with a brush.

-Do not cover plastic parts.