To set comfortable
To use the Unit with PASGT head and helmet mount unscrew the grooved pad (2, Fig. 3) from the swing arm mount and screw on the US type clip (6, Fig. 3) using four screws (Fig. 3) instead. US type helmet clip is optional and must be ordered seperately.
To switch between left and right eye, press the flip button (5, Fig.
3)on the mount and rotate it respectively until you hear an audible click.
Swinging head mounted Unit for unobstructed view
When the head mounted Unit is not in use you can raise it to clear the view without taking the headgear off by using the “flip/flop” feature. To swing the Unit from the view press the button (5, Fig. 3) and raise the device until you hear a click. In “Auto” position of the switch, the monocular will turn off automatically. Reverse the operation to return the Unit to working position.
Using IR illuminator
In case of insufficient light when observing a close object turn on the IR illuminator by turning the On/Off/IR/Auto switch.
Red indicator visible through the eyepiece will warn you when the IR illuminator is on.
Note: The IR illuminator is visible to anybody equipped with a night vision device and can disclose the user’s presence.
14