Should the monocular pair fail to be locked relative to the unit fixing assembly, proceed as follows:

Move knob (2) (Ref. Fig. 6.4) to the top position (the hinged joint, in this case, will be fully released).

Pull out plate (3), which retains screw (4) in the locked position, with your thumb and forefinger, turn it to the next locking position in the clockwise direction and release the plate. The plate shall be set to a new locking position (Ref. Step 6.2.2).

This done, lock the hinged joint linking the monocular pair to the unit fixing assembly again by applying an effort to knob (2) so as to bring it down as far as it will go.

If the monocular locking continues to fail, carry out the above procedure one more time.

6.2.4Take power supply components (two batteries of type size AA R6 1.5V or rechargeable batteries) out of the case. When using the rechargeable batteries, first charge them in accordance with the Manual furnished with the battery-charging unit.

6.2.5Insert two batteries into the recess of guide (8) with the positive contact directed inwards by first unscrewing and removing cap-switch (5), and then screw it in fully in the clockwise direction.

6.2.6Release knob (2) and set the top portion of the fixing assembly perpendicular to the axes of monocular (28) and monocular (29). While holding the fixing assembly in one hand, displace the monocular pair with the other hand forward and downward until they are butted up against the cruciform guides of the fixing assembly. Once completed, tighten the knob to lock the monocular pair in the desired position.

WARNING: NEGLECT OF THE REQUIREMENTS DESCRIBED IN THE ABOVE STEP MAY RESULT IN EYE INJURY DURING THE COMPLETION OF FURTHER PREPARATORY OPERATIONS.