NVS 6

MANUAL

8 OPERATIONAL STATUS CHECK

8.1In the course of the NVS 6 service, it is essential to continually carry out its inspection. The inspection shall be accomplished during all kinds of maintenance checks with the aim of determining the unit operational status, and detecting in due time its defects and their correction. The operational status of the unit is exemplified by its serviceability, completeness of its standard set, and readiness for use.

8.2The list of the basic checks of the NVS 6 and its accessories for operational status (inspection procedures) is presented in Table 3.

Table 3

Procedure

Inspection method

Technical requirements

 

 

 

1 Unit standard

Check the standard

The unit standard set

set inspection for

delivery set against

shall comply with the

full complement

the list of the unit com-

standard delivery set

 

ponents in the Log

specified in the NVS 6 Log

 

Book.

Book.

 

 

 

2 External

Inspect the unit for

The external surfaces of

inspection of

external condition (vi-

the unit and its accessories

the unit and its

sually).

shall not be affected by

accessories

 

cracks, dents, traces of cor-

 

 

rosion and other defects.

 

 

The lenses and

 

 

eyepieces shall be free

 

 

from cracks, spots of

 

 

grease and dirt.

 

 

 

3 Serviceability

The procedure for

With the unit energized

test of the unit and

serviceability test is

(either from the helicopter

its accessories

described in Section 6

electrical system via the

 

of this Manual.

voltage converter, or from

 

 

 

Table 3, cont'd

Page 38

Page 43
Image 43
Newcon Optik NVS 6 operation manual Operational Status Check