Whynter BWR-171DS, DWR-401DS manual Troubleshooting, Display “E0”, “E1”. “E2”

Models: BWR-171DS DWR-401DS

1 18
Download 18 pages 52.61 Kb
Page 17
Image 17
Display “E0”, “E1”. “E2”,

Troubleshooting

Problem

Possible Causes

 

Solutions

 

 

 

 

Display “E0”, “E1”. “E2”,

“E0” indicates the communication

Call for service

“E3”, “E4”, “E5” or “E7”

error for 3 zone models

 

 

 

“E1” or “E2” indicates that the air

 

 

 

temperature sensor is failed

 

 

 

“E3” or “E4” indicates that the de-

 

 

 

frost sensor in the evaporator is

 

 

 

failed

 

 

 

E5” indicates the defrost heater fail-

 

 

 

ure

 

 

 

E7” indicates the door switch failure

 

 

 

 

 

 

The alarm sounds and the

Door has been opened for more

Close the door

temperature display flashes

than 60 seconds

 

 

 

The appliance door being opened

Do not open the door more often than

 

too often

 

necessary

 

The ventilation opening being cov-

Clear the obstructions and clean the

 

ered or too dusty

 

dust

 

A lengthy interruption to the power

Leave the appliance to work for a while

 

supply

 

until the set temperature has been

 

A large amount of bottles has been

 

reached.

 

 

 

 

added to the unit

 

 

 

 

 

The icon “--” is lit up and

The display temperature is out of

Only temperatures within the range

flashing in the temperature

the range

 

16~99°F/-9~37°C the appliance can

display

 

 

display will be shown. If the tempera-

 

 

 

ture is not within this range, the icon “--

 

 

 

” will be displayed instead. That is nor-

 

 

 

mal

 

 

 

 

17

Page 17
Image 17