Natural Gas Conversion Style# 710-0650

AWARNING! FALURE TO HEED THESE WARNINGS COULD RESULT IN A FIRE OR EXPLOSION THAT

COULD CAUSE SERIOUS BODILY INJURY, DEATH OR PROPERTY DAMAGE.

Installation of this Natural Gas Conversion kit must be performed by a QUALIFIED GAS TECHNICIAN ONLY. DO NOT ATTEMPT TO INSTALL THIS KIT YOURSELF. Improper installation could result in a gas leak which could cause a fire or explosion and cause serious bodily injury, death or property damage. Leaks due to improper installation could occur immediately or slowly over time. If you hear any unusual noises or leaks, smell gas or unusual odors, or notice anything unusual with the operation of your gas appliance after the installation, immediately shut off the gas supply and discontinue use until the appliance is repaired by a QUALIFIED GAS TECHNICIAN.

If there are damaged or missing parts when you unpack this kit, call 1-800-913-8999. DO NOT have your QUALIFIED GAS TECHNICIAN attempt to install this kit until you receive replacement for any damaged or missing parts.

Orifice Chart

The different burner valves in this grill have different BTU ratings. This means that the amount of gas coming from each orifice varies in order to create the BTU's. The holes in the orifices themselves are drilled to different sizes so as to allow the proper amount of gas to flow through them. Please note the chart below as an easy reference for the various orifice opening sizes for the different valves in the grill.

720-0650B,

730-0650B /810-0010,

830-0010

orifices size

 

 

Orifice Sizes and BTU Ratings

 

 

 

LP

 

NG

 

 

Orifice

 

Orifice

 

Components

Size

BTU

Size

BTU

Main Burner

0.94

10K

1.55

10K

Rear Burner

1.07

13K

1.84

13K

Searing Side Burner

1.15

15K

1.90

15K

Page 2
Image 2
Nexgrill Gas Grill warranty Natural Gas Conversion Style#, 720-0650B 730-0650B 830-0010 Orifices size