122

r

3

Select a preset.

Press the 

L

 (

U

) button and rotate the sub-command dial until the desired 

white balance preset (d-1 to d-4) is displayed in the control panel.

4

Select direct measurement mode.

Release the 

L

 (

U

) button briefly and then press the 

button until the 

L

 icon in the control panel starts to 

flash. A flashing 

D

 will also appear in the viewfinder. 

The displays will flash for about six seconds.

5

Measure white balance.

Before the indicators stop flashing, frame the reference 

object so that it fills the viewfinder and press the 

shutter-release button all the way down. The camera 

will measure a value for white balance and store it in the preset selected in Step 

3. No photograph will be recorded; white balance can be measured accurately 

even when the camera is not in focus.

L

 (

U

) button

Sub-command dial

Control panel

A

Protected Presets

If the current preset is protected (

0

127), 

3

 will flash in the control panel and viewfinder 

if you attempt to measure a new value.

Control panel

Viewfinder

Page 148