147

l

A

Aperture, Sensitivity, and Flash Range 

Flash range varies with sensitivity (ISO equivalency) and aperture.

Aperture at ISO equivalent of 

Range 

100 

200 

400

800

1600

3200

6400

m 

ft 

1.4

2

2.8

4

5.6

8

11

0.7–8.5

2ft 4in.–27ft 11in.

2

2.8

4

5.6

8

11

16

0.6–6.0

2ft–19ft 8in.

2.8

4

5.6

8

11

16

22

0.6–4.2

2ft–13ft 9in.

4

5.6

8

11

16

22

32

0.6–3.0

2ft–9ft  10in.

5.6

8

11

16

22

32

—

0.6–2.1

2ft–6ft 11in.

8

11

16

22

32

—

—

0.6–1.5

2ft–4ft  11in.

11

16

22

32

—

—

—

0.6–1.1

2ft–3ft 7in.

16

22

32

—

—

—

—

0.6–0.8

2ft–2ft 7in.

The built-in flash has a minimum range of 0.6 m (2 ft).

In mode 

P

, the maximum aperture (minimum f-number) is limited according to ISO 

sensitivity, as shown below:

Maximum aperture at ISO equivalent of:

100

200

400

800

1600

3200

6400

2.8

3.5

4

5

5.6

7.1

8

If the maximum aperture of the lens is smaller than given above, the maximum value for 

aperture will be the maximum aperture of the lens.

A

See Also

See page 149 for information on locking flash value (FV) for a metered subject before 

recomposing a photograph. 

For information on auto FP high-speed sync and choosing a flash sync speed, see Custom 

Setting e1 (

Flash sync speed

, 

0

234). For information on choosing the slowest shutter 

speed available when using the flash, see Custom Setting e2 (

Flash shutter speed

, 

0

235). 

For information on flash control and using the built-in flash in commander mode, see 

Custom Setting e3 (

Flash cntrl for built-in flash

, 

0

236). 

See page 292 for information on using optional flash units.

Page 173