Troubleshooting—continued
LCD panel | Viewfinder | Cause | Remedy | Page |
|
|
|
|
|
HI appears | HI appears | • Overexposure may | • In P mode, use ND filter. | |
|
| have occurred. | • In S mode, select faster | 48 |
|
|
| shutter speed. | 50 |
|
|
| • In A mode, select smaller | |
|
|
| aperture (larger f- |
|
|
|
| number). |
|
|
|
| (If the warning indication |
|
|
|
| remains after performing |
|
|
|
| above remedies in S or A |
|
|
|
| mode, use ND filter as |
|
|
|
| well.) |
|
|
|
|
|
|
Lo appears | Lo appears | • Underexposure may | • In P mode, use flash. | |
|
| have occurred. | • In S mode, select slower | 48 |
|
|
| shutter speed. | 50 |
|
|
| • In A mode, select larger | |
|
|
| aperture (smaller f- |
|
|
|
| number). |
|
|
|
| (If the warning indication |
|
|
|
| remains after performing |
|
|
|
| above remedies in S or A |
|
|
|
| mode, use flash as well.) |
|
|
|
|
|
|
Electronic | Electronic | • Subject brightness is | • When the subject is bright, | 53 |
analog exposure | analog exposure | beyond camera’s | use ND filter and when the |
|
display blinks | display blinks | exposure range. | subject is dark, use flash. |
|
|
|
|
|
|
buLb blinks | buLb blinks | • Shutter speed is set to | • Cancel the buLb by | 48, 62 |
|
| buLb in S mode. | selecting 30 sec. or faster |
|
|
|
| shutter speed, or select M |
|
|
|
| mode to perform Long |
|
|
|
| Time Exposure. |
|
|
|
|
|
|
¡ or ™ blinks | A appears | • | • If | 32, |
|
| attached, or no lens is | attached, set the | 46, |
|
| attached in P or S | exposure mode to A or M. | |
|
| mode. |
|
|
|
|
|
|
|
Shutter speed | 25o appears | • Shutter speed faster | • Release the shutter as it | 84 |
indication blinks |
| than sync speed is | is to take a flash picture. |
|
|
| selected in S or M | (Shutter speed |
|
|
| mode. | automatically shifts to |
|
|
|
| 1/250 sec.) |
|
|
|
|
|
|
LCD panel | Viewfinder | Cause | Remedy | Page |
|
|
|
|
|
|
|
|
|
— | fi blinks | • Flash has fired at full | • Shoot again after | 79, 85 |
|
|
| for 3 sec. | output and | confirming focus |
|
|
|
| after flash | underexposure may | distance, aperture or |
|
|
|
|
| have occurred. | flash shooting distance |
|
|
|
|
|
| range. |
|
|
|
|
|
|
|
|
|
|
Err blinks | Err blinks | • Malfunction detected. | • Release shutter again. |
|
|
|
|
|
| If the warning |
|
|
|
|
|
| indication remains, or |
|
|
|
|
|
| this warning appears |
|
|
|
|
|
| frequently, contact |
|
|
|
|
|
| authorized Nikon dealer |
|
|
|
|
|
|
|
| Miscellaneous | |
|
|
| or service center. |
|
| |
|
|
|
|
|
| |
|
|
|
|
|
|
|
FuL blinks | FuL blinks | • Shooting data is full in | • Turn the power switch |
|
|
|
|
| F100’s memory. | off once and on again. |
|
|
|
|
|
| Warning indication |
|
|
|
|
|
| disappears and |
|
|
|
|
|
| additional data will not |
|
|
|
|
|
| be recorded until the |
|
|
|
|
|
| data in the memory is |
|
|
|
|
|
| erased. |
|
|
|
|
|
|
|
|
|
|
& blinks | — | • | • Use a Speedlight | 81 |
|
|
|
|
| equipped with |
|
|
|
|
| with Slow Sync is set | Reduction function. |
|
|
|
|
| when a Speedlight |
|
|
|
|
|
| without |
|
|
|
|
|
| Reduction function is |
|
|
|
|
|
| attached. |
|
|
|
|
|
|
|
|
|
|
|
• Film rewind stops | • Turn the power switch | 29, 35 |
|
| ||
frame counter | frame counter | midway due to low | off, replace batteries |
|
|
|
blink | blink | battery power. | with new ones and |
|
|
|
|
|
| rewind the film again. |
|
|
|
|
|
|
|
|
|
|
In certain cases, due to static electricity or poorly loaded batteries, the F100’s microcomputer may turn the camera off, even with fresh, properly installed batteries. For the same reason, the film may not advance properly. In each of these cases, to resume operation, simply turn the power off, then turn it on again. Or, remove and reinstall the batteries.
100 | 101 |