Niles Audio SI-1230 Step, Description, want to control, current capability of 150 mA, FG00724

Models: SI-1230

1 32
Download 32 pages 47.55 Kb
Page 24
Image 24
want to control.

Installation

Setting the Turn-On

Mode Switch

The SI-1230 has three turn-on modes. Select the mode you want by sliding the mode switch. See Installation Considerations on page 14 for more information about each of the turn-on modes.

TIP: To conserve energy set the TURN ON mode to either AUDIO SENSE or TRIGGER INPUT. Use of the CONSTANT mode will prevent the amplifier from turning off when not in use wasting energy.

TURN ON MODE

AUDIO SENSE 3-30V

CONSTANTAC/DC TRIGGER INPUT

Slide the switch with either

your fingernail or 1/8”

slotted screwdriver blade

The Control Output

This terminal provides a 12V DC signal suitable for triggering Niles automated switchers, some motorized screens, some electric curtain controls, etc. This voltage is present only when the amplifier is active or on. When the amplifier turns off, the 12V signal is off.

STEP

DESCRIPTION

 

 

 

1.

Check the requirements of the device you

The control output has a maximum

 

want to control.

current capability of 150 mA.

 

 

 

2.

Connect the 3.5 mm Jack to the control

Niles makes an accessory cable plug

 

output maintaining proper polarity

 

FG00724.

 

(tip = +).

 

 

 

 

 

24

 

WWW.NILESAUDIO.COM

 

Page 24
Image 24