Nilfisk-Advance America BR 600S Series manual English / A-7, Install the Batteries

Models: BR 600S Series

1 40
Download 40 pages 33.12 Kb
Page 7
Image 7

ENGLISH / A-7

DESCRIPTION OF THE BATTERY CONDITION INDICATORS

The battery condition indicator (K) consists of three lights, a green, a yellow, and a red. The voltage indication will change based on the cutoff level (standard or alternate) selected in the control unit. The battery voltage ranges for the various indications are listed below:

 

Standard

 

Alternate

Green

34.00+

 

34.50+

Green & Yellow

33.00-33.99

34.00-34.49

Yellow

32.00-32.99

33.50-33.99

Yellow & Red

31.50-31.99

33.00-33.49

Red

31.00-31.49

32.50-32.99

Flashing Red/Cutoff

<31.00

<32.50

 

NOTE: Refer to service manual for selection of alternate cut-off level. Once the low voltage cutout level has been reached (flashing red indicator) the batteries must be FULLY recharged to reset the battery condition indicator. The scrub system will not function until the indicator has been reset.

INSTALL THE BATTERIES

WARNING !

Use extreme caution when working with batteries. Sulfuric acid in batteries can cause severe injury if allowed to contact the skin or eyes. Explosive hydrogen gas is vented from inside the batteries through openings in the battery caps. This gas can be ignited by any electrical arc, spark or flame.

When Servicing Batteries...

*Remove all jewelry.

*Do not smoke.

*Wear safety glasses, a rubber apron and rubber gloves.

*Work in a well-ventilated area.

*Do not allow tools to touch more than one battery terminal at a time.

CAUTION !

Electrical components in this machine can be severely damaged if the batteries are not installed and connected properly. Batteries should be installed by Nilfisk-Advance or by a qualified electrician.

1Turn the Key Switch (J) off (O) and remove the key. Then swing open the Battery Compartment Cover (16).

2Using (2) people and an appropriate lifting strap, carefully lift the batteries into the compartment tray exactly as shown. Refer to decal 56015168 battery cable layout.

3See Figure 1. Install battery cables as shown and tighten the nuts on the battery terminals.

4Install the battery boots and secure tightly to the battery cables with the supplied tie straps.

5Connect the battery pack connector to the machine connector (22) and close the battery compartment cover.

FIGURE 1

revised 10/06

FORM NO. 56041554 - Advenger, AdvengerAXP / BR 600S series - A-7

Page 7
Image 7
Nilfisk-Advance America BR 600S Series manual English / A-7, Description of the Battery Condition Indicators