Nilfisk-Advance America GD 930S2 Electrical Connections, Only applicable to UK, Grounded Machines

Models: GD 930S2 GD 930

1 32
Download 32 pages 27.81 Kb
Page 9
Image 9
ELECTRICAL CONNECTIONS

ELECTRICAL CONNECTIONS

(Only applicable to UK)

GROUNDED MACHINES

IMPORTANT

240 volt 50 Hz. machines are fitted with a 13 amp. 3 pin moulded plug. the plug is fitted with a 7 amp. detachable fuse. The correct replacement for the fuse is identified by marking or colour coding. Only fuses that are ASTA approved to BS 1362 should be fitted. Never use the plug without the fuse cover fitted. Replacement fuse covers are available at any electrical retail outlet. If the available socket outlet is not suitable for the plug supplied, the plug must be cut off and an appropriate plug fitted. The plug thus cut off MUST BE DESTROYED for safety reasons before being disposed of. Machines built for other voltages and frequencies are not normally supplied with a fitted plug. If it is necessary to fit a plug, the wires in this power supply cord are coloured in accordance with the following code:

GREEN & YELLOW-EARTH

BLUE-NEUTRAL

BROWN-LIVE

To connect the new plug:

The wire which is coloured green & yellow must be connected to the terminal in the plug which is marked with the letter 'E' or by the safety earth symbol

or coloured green or

green & yellow. The wire which

is coloured blue must be connected to the terminal in the plug which is marked with the letter 'N' or is coloured black or blue. The wire which is coloured brown must be connected to the terminal in the plug which is marked with the letter 'L' or is coloured red or brown. If the plug to be fitted does not conform to the above notation then consult a qualified electrician.

DOUBLE-INSULATED MACHINES

IMPORTANT

240 volt 50 Hz. machines are fitted with a 13 amp. 3 pin moulded plug. the plug is fitted with a 13 amp. detachable fuse. The correct replacement for the fuse is identified by marking or colour coding.

Only fuses that are ASTA approved to BS 1362 should be fitted. Never use the plug without the fuse cover fitted. Replacement fuse covers are available at any electrical retail outlet.

If the available socket outlet is not suitable for the plug supplied, the plug must be cut off and an appropriate plug fitted. The plug thus cut off MUST BE DESTROYED for safety reasons before being disposed of.

Machines built for other voltages and frequencies are not normally supplied with a fitted plug.

If it is necessary to fit a plug, the wires in this power supply cord are coloured in accordance with the following code:

BLUE-NEUTRAL

BROWN-LIVE

To connect the new plug:

If using a three-pin plug, do not make any connection to the the terminal in the plug which is marked with the letter ‘E’ or by the safety earth symbol orcolouredgreenorgreen

&yellow. This machine is double-insulated and no earth connection is necessary.

The wire which is coloured blue must be connected to the terminal in the plug which is marked with the letter ‘N’ or is coloured black or blue.

The wire which is coloured brown must be connected to the terminal in the plug which is marked with the letter ‘L’ or is coloured red or brown.

If the plug to be fitted does not conform to the above nota- tion then consult a qualified electrician.

9

822 9393 000 Instruction for use GD 930 EU.indd 9

2008-06-26 13:06:13

Page 9
Image 9
Nilfisk-Advance America GD 930S2 Electrical Connections, Only applicable to UK, Grounded Machines, To connect the new plug