ATTIX
6 After finishing work
6.1Switching the vacuum
cleaner off and storage
1.After picking up hazardous dust, vacuum clean the out- side of the cleaner.
2.Switch off the vacuum clean- er and pull the mains plug out of the socket.
3.Wind up the power cord and hang it on the handle.
4.Empty the tank and clean the vacuum cleaner.
5.After picking up liquids: Store the upper section of the cleaner separately so that the filter element can dry.
6.Store the vacuum cleaner in a dry room where it is protected from unauthorized use.
7 | Maintenance |
|
7.1 | Maintenance plan |
|
|
|
|
| When replacing | After finishing As required |
| the filter bag, | work |
| waste bag or filter |
|
| element |
|
7.2.1check the antistatic Clamps
7.2.2Replacing the waste bag
7.2.3Replacing the filter bag
7.2.4Emptying the dirt tank
7.2.5Replacing filter element
7.2.6Replace the filter for air supply to motor
7.2Maintenance work 7.2.1 check the antistatic
clamps
Do not use the cleaner with damaged or missing antistatic clamps. Risk of explosion due to static discharge in explosive atmospheres.
1 |
|
1 | 1 |
1 |
|
| 1 |
1.Check the anti- static clamps
(1)for dam- age and have them replaced by
8